Page 2
0
1OP1
0
30 – February 2018
Maintenance
Lubrication
Operator may perform routine maintenance only. Lubrication listed as Scheduled Maintenance must be performed by a qualified
service technician.
Lubrication
No.
ITEM
SPECIFICATION
FREQUENCY
1
Hydraulic
Reservoir
Mobile Fluid DTE 10, DTE 13M or AW32
Routine Maintenance
Check level daily
Scheduled Maintenance
Change yearly or every 600 hours, whichever occurs
first
Do not substitute other fluids as pump
damage may result.
Fill to the middle of the dipstick with
platform in the stowed position.
2
Hydraulic Cap
Breather Filter
Breather Filter
(located inside filler cap)
Scheduled Maintenance
Normal Conditions
Change every six months or 300 hours,
whichever occurs first
Severe Conditions--very dusty, exceptionally
hot or exceptionally cold conditions
Change every three months or 150 hours, whichever
occurs first
13327
FULL
ADD
1030-PA