background image

T X 3 5 0 0 S  

I N S T R U C T I O N   M A N UA L  

PA G E   2 7

This warranty against defects is given by Standard Communications Pty 

Ltd ACN 000 346 814 (We, us, our or GME). Our contact details are set 

out in clause 2.7.

1.  Consumer guarantees

1.1   Our goods come with guarantees that cannot be excluded under 

the Australian Consumer Law. You are entitled to a replacement 

or refund for a major failure and for compensation for any other 

reasonably foreseeable loss or damage. You are also entitled to 

have the goods repaired or replaced if the goods fail to be of 

acceptable quality and the failure does not amount to a major 

failure.

1.2   To the extent we are able, we exclude all other conditions, 

warranties and obligations which would otherwise be implied.

2.   Warranty against defects

2.1   This warranty is in addition to and does not limit, exclude or 

restrict your rights under the Competition and Consumer Act 2010 

(Australia) or any other mandatory protection laws that may apply.

2.2   We warrant our goods to be free from defects in materials and 

workmanship for the warranty period (see warranty table) from 

the date of original sale (or another period we agree to in writing). 

Subject to our obligations under clause 1.2, we will at our option, 

either repair or replace goods which we are satisfied are defective. 

We warrant any replacement parts for the remainder of the period 

of warranty for the goods into which they are incorporated.

2.3   To the extent permitted by law, our sole liability for breach of a 

condition, warranty or other obligation implied by law is limited 

 

  (a)  in the case of goods we supply, to any one of the following as 

we decide – 

 

   

(i)   the replacement of the goods or the supply of equivalent 

goods;

 

   

(ii)   the repair of the goods; 

 

   

(iii)   the cost of repairing the goods or of acquiring equivalent 

goods; 

 

  (b)   in the case of services we supply, to any one of the following 

as we decide – 

 

   

(i)   the supplying of the services again; 

 

   

(ii)  the cost of having the services supplied again.

2.4   For repairs outside the warranty period, we warrant our repairs 

to be free from defects in materials and workmanship for three 

months from the date of the original repair. We agree to re-repair or 

replace (at our option) any materials or workmanship which we are 

satisfied are defective.

 2.5   We warrant that we will perform services with reasonable care and 

skill and agree to investigate any complaint regarding our services 

made in good faith. If we are satisfied that the complaint is justified, 

and as our sole liability to you under this warranty (to the extent 

permitted at law), we agree to supply those services again at no 

extra charge to you.

2.6   To make a warranty claim you must before the end of the 

applicable warranty period (see warranty table), at your own cost, 

return the goods you allege are defective, provide written details 

of the defect, and give us an original or copy of the sales invoice or 

some other evidence showing details of the transaction.

2.7   Send your claim to: Standard Communications Pty Ltd.  

PO Box 96 Winston Hills, NSW 2153, Australia.  
Tel: (02) 8867 6000 Fax: (02) 8867 6199 
Email: [email protected]

2.8   If we determine that your goods are defective, we will pay for 

the cost of returning the repaired or replaced goods to you, and 

reimburse you for your reasonable expenses of sending your 

warranty claim to us. 

3.  What this warranty does not cover

3.1   This warranty will not apply in relation to: 
 

  (a)  goods modified or altered in any way;

 

   (b)   defects and damage caused by use with non Standard 

Communications products;

 

   (c)   repairs performed other than by our authorised 

representative;

 

   (d)   defects or damage resulting from misuse, accident, impact or 

neglect;

 

   (e)   goods improperly installed or used in a manner contrary to 

the relevant instruction manual; or

 

   (f)   goods where the serial number has been removed or made 

illegal.

4.  Warranty period

4.1   We provide the following warranty on GME and Kingray products. 

No repair or replacement during the warranty period will renew or 

extend the warranty period past the period from original date  

of purchase.

STANDARD COMMUNICATIONS CONTRACT WARRANTY AGAINST DEFECTS

PRODUCT TYPE

WARRANTY 

PERIOD

All fixed mount ‘S’ model UHF CB radios

5 years

Содержание TX3500S

Страница 1: ...I N S T R U C T I O N M A N U A L Compact 5 watt UHF CB radio...

Страница 2: ...Voltage Warning 20 ANTENNA CONNECTION 21 NOISE SUPPRESSION 21 CTCSS TONE FREQUENCY CHART 22 DCS TONE CHART 23 UHF CB OPERATING FREQUENCIES 24 SPECIFICATIONS 25 SC CONTRACT WARRANTY AGAINST DEFECTS 27...

Страница 3: ...adio the speech may sound loud and distorted simply adjust your radio volume for best performance When an older wideband radio receives a signal from a new narrowband radio the speech may sound quiet...

Страница 4: ...ference caused by strong local signals on adjacent channels and prevents these from opening your Squelch ASM also minimises distortion on reception by fine tuning the receiver frequency to match that...

Страница 5: ...QL LVL PUSH HOLD MENU Channel Control LCD Liquid Crystal Display Volume Control REAR PANEL LCD PANEL FRONT PANEL CONTROLS Ext Speaker Socket Rear Microphone Socket Antenna Socket DC Socket Channel Dis...

Страница 6: ...tivity level has been factory set to provide optimum performance under most operating conditions If required the sensitivity level can be adjusted to suit changing conditions To adjust the Squelch sen...

Страница 7: ...hannel Control to return to normal operation NOTE The Menu function will automatically time out after 6 seconds if no further adjustments have been made BEEP TONE VOLUME The Key Beeps provide audible...

Страница 8: ...otate the Channel Control clockwise again to select ON on is displayed 5 Rotate the Channel Control counter clockwise to select OFF oF is displayed When finished press and hold the Channel Control to...

Страница 9: ...gher CH 31 The repeater hears your signal on CH 31 and retransmits it on CH 1 for others to hear CHANNEL 31 CHANNEL 1 CHANNEL 1 CHANNEL 31 VEHICLE SIMPLEX REPEATER OPERATION VEHICLE REPEATER STATION T...

Страница 10: ...nel Control to select oS Open Scan GS Group Scan or nS Network Scan When finished press and hold the Channel Control to return to normal operation NOTE Network Scan is disabled by default and will not...

Страница 11: ...eard when you press the SCAN key and the command will be ignored Operating in the Open Scan mode If a busy channel is found scanning will pause to allow the signal to be heard and will remain there fo...

Страница 12: ...r channel scanning will pause on that channel and will remain there while the channel is busy as long as there are no signals on the Priority channel During this time the receiver will continue to che...

Страница 13: ...nes 01 104 A4 When DCS tones are selected flashes Netscan off CTCSS indicator Netscan with CTCSS tone 50 DCS indicator Netscan with DCS tone 104 A4 Since there are 104 DCS tones and only two character...

Страница 14: ...l remains free of other signals This allows the radios in the group to respond more quickly to further transmissions from others in the group If at any time a signal from outside your Net Scan group a...

Страница 15: ...ished press and hold the Channel Control to return to normal operation NOTE The tone you select will be used for all channels that have Silent enabled Rotate Left Rotate Right oF CTCSS Tones 1 50 DCS...

Страница 16: ...otate the Channel Control to the right to enable busy lockout on will be displayed 5 Rotate the Channel Control to the left to disable busy lockout oF will be displayed When finished press and hold th...

Страница 17: ...F 01 50 with icon flashing CTCSS Tones 01 A4 with icon flashing DCS Codes nS Netscan oF Netscan OFF CTCSS Tones 01 50 with icon flashing DCS Codes 01 104 A4 with icon flashing St Silent Squelch Tail o...

Страница 18: ...in a less audible location and an extension speaker used instead When installing the radio avoid mounting it close to heaters or air conditioners Console mounting A flush mounting DIN adapter MBD001 i...

Страница 19: ...remove simply insert the end of a paper clip or similar into the small slot in the edge of the cover and lift the cover away from the panel 2 Place the microphone plug so the plastic tab faces downwa...

Страница 20: ...io turns ON and OFF with ignition switch RED BLACK Chassis Car battery Ingnition Switch Radio turns ON and OFF with the ignition switch Connect the radio s negative black lead to the vehicle s chassis...

Страница 21: ...sceivers results in a high level of resistance to ignition and electrical interference However in some installations it may be necessary to take additional steps to help reduce or eliminate noise inte...

Страница 22: ...8 41 165 5 3 74 4 16 114 8 29 179 9 42 171 3 4 77 0 17 118 8 30 186 2 43 177 3 5 79 7 18 123 0 31 192 8 44 183 5 6 82 5 19 127 3 32 203 5 45 189 9 7 85 4 20 131 8 33 210 7 46 196 6 8 88 5 21 136 5 34...

Страница 23: ...24 134 42 246 60 351 78 465 96 664 7 043 25 143 43 251 61 356 79 466 97 703 8 047 26 145 44 252 62 364 80 503 98 712 9 051 27 152 45 255 63 365 81 506 99 723 10 053 28 155 46 261 64 371 82 516 100 73...

Страница 24: ...31 477 175 51 476 6875 71 477 1875 12 476 700 32 477 200 52 476 7125 72 477 2125 13 476 725 33 477 225 53 476 7375 73 477 2375 14 476 750 34 477 250 54 476 7625 74 477 2625 15 476 775 35 477 275 55 47...

Страница 25: ...lts DC Battery Polarity Negative Earth Standard Test Voltage 13 8 volts DC Overvoltage Protection 30 volts DC maximum At 18 volts DC the channel display flashes Hi DC for 5 seconds on receive The RF p...

Страница 26: ...e 45 dB unweighted Receive Frequency Response 6 dB Octave de emphasis 300 Hz to 3 kHz 1 3 dB Current Consumption 175 mA muted 750 mA full volume Conducted Spurious Emission 70 dBm MECHANICAL SPECIFICA...

Страница 27: ...e warranty period we warrant our repairs to be free from defects in materials and workmanship for three months from the date of the original repair We agree to re repair or replace at our option any m...

Страница 28: ...re information call or visit us A division of Standard Communications Pty Ltd Head Office PO Box 96 Winston Hills NSW 2153 Australia New Zealand PO Box 58446 Botany Auckland 2163 NZ T 09 274 0955 All...