background image

3

RF RADIATION INFORMATION

RF RADIATION PROFILE

Your radio is designed and tested to comply with a number 
of national and international standards and guidelines 
(listed below) regarding human exposure to radio frequency 
electromagnetic energy. This radio complies with the IEEE 
and ICNIRP exposure limits for occupational/controlled RF 
exposure environment at operating duty factors of up to 50% 
transmitting and is authorised by the FCC for occupational 
use only. In terms of measuring RF energy for compliance with 
the FCC exposure guidelines, your radio radiates measurable 
RF energy only while it is transmitting (during talking in PTT 
mode), not when it is receiving (listening) or in standby mode.

The device complies with SAR and/or RF field strength limits of 
RSS-102 requirements.

RF RADIATION SAFETY

In order to ensure user health, experts from relevant industries 
including science, engineering, medicine and health work 
with international organizations to develop standards for safe 
exposure to RF radiation. These standards consist of:

   United States Federal Communications Commission, Code 

of Federal Regulations; 47CFR part 2 sub-part J;

   American National Standards Institute (ANSI)/Institute of 

Electrical and Electronic Engineers (IEEE) C95. 1-1992;

   Institute of Electrical and Electronic Engineers (IEEE) C95. 

1-1999;

   International Commission on Non-Ionizing Radiation 

Protection (ICNIRP) 1998;

FCC Regulations

Federal Communication Commission (FCC) requires that all 
radio communication products should meet the requirements 
set forth in the above standards before they can be marketed 
in the US, and the manufacturer shall post a RF label on the 
product to inform users of operational instructions, so as to 
enhance their occupational health against exposure to  
RF energy.

Part 15 Compliance

This equipment has been tested and found to comply with 
the limits for a Class B digital device, pursuant to part 15 
of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses and 
can radiate radio frequency energy and, if not installed and 
used in accordance with the instructions, may cause harmful 
interference to radio communications. 
However, there is no guarantee that interference will not occur 
in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of 
the following measures:   

  Reorient or relocate the receiving antenna.

   Increase the separation between the equipment and 

receiver. 

   Connect the equipment into an outlet on a circuit different 

from that to which the receiver is connected. 

   Consult the dealer or an experienced radio/TV technician 

for help. Note: ’Changes or modifications to this unit not 
expressly approved by the party responsible for compliance 
could void the user’s authority to operate the equipment.’

EU Regulatory Conformance

As certified by the qualified laboratory, the product is in 
compliance with the essential requirements and other relevant 
provisions of the Directive 1999/5/EC. Please note that the 
above information is applicable to EU countries only.

    

O-ring

Rotate until tight

Antenna

Rubber cap

Ear / mic  
accessory jack 
(HS014)

Содержание GX625

Страница 1: ...418 4 PART 311032 JIRA REFERENCE GRA 1807 SUPPLIER Shenzhen Jiuzhou Himunication MPE PRINTING SPECIFICATIONS GX625 IM Flat size 296 mm w x 180 mm h Folded down 148 mm x 180 mm Stock 130gsm Gloss Lamin...

Страница 2: ...ign and manufacturing quality To ensure you are familiar with the operation and features of your radio and in order to obtain the best performance please read this manual thoroughly before operation C...

Страница 3: ...marketed in the US and the manufacturer shall post a RF label on the product to inform users of operational instructions so as to enhance their occupational health against exposure to RF energy Part...

Страница 4: ...r if necessary Persons operating a VHF marine radio without holding an appropriate qualification or being under the supervision of an appropriately qualified person may be breaching the Radio communic...

Страница 5: ...5 CONTROLS GX625 Antenna PTT Keypad Microphone Ear mic accessory jack HS014 Display Power switch Speaker...

Страница 6: ...Save Delete Memory Channel Up Down Channel Up Down Channel Fast Up Down CH WX UIC Channel Weather Band Selection VOL SQL VOLUME Set SQUELCH Set Channel Weather Band Up Channel 16 Down Scan Private Sc...

Страница 7: ...ing HI or LO icon will be displayed on the LCD NOTE Some channels may be permanently restricted to Low or High power Pressing the key on these channels will result in an error beep BACK LIGHT The back...

Страница 8: ...ess and hold the key to store the selected channel as a memory channel The M icon indicates the current channel has been saved in the memory 3 Repeat to add other channels You can store as many channe...

Страница 9: ...ans the memory channels for signals To deactivate the Priority Memory Scan briefly press the key again SCAN disappears from the display Press the key to exit the memory mode DUAL WATCH The Dual Watch...

Страница 10: ...ce Port Operations and Ship Movement 06 156 300 156 300 x Inter ship 1 07 156 350 160 950 Public Correspondence Port Operations and Ship Movement 08 156 400 156 400 x Inter ship 09 156 450 156 450 x I...

Страница 11: ...ovement 65 156 275 160 875 Public Correspondence Port Operations and Ship Movement 65A 156 275 156 275 Non Commercial 66 156 325 160 925 Public Correspondence Port Operations and Ship Movement 66A 156...

Страница 12: ...ls 15 and 17 may also be used for on board communications provided the effective radiated power does not exceed 1 watt 5 The use of Channels 75 and 76 should be restricted to navigation related commun...

Страница 13: ...uard only 22A 157 100 157 100 x Coast Guard Liaison and Maritime Safety Information Broadcasts Broadcasts announced on channel 16 23A 157 150 157 150 x U S Coast Guard only 24 157 200 161 800 Public C...

Страница 14: ...ions Inter ship only 78A 156 925 156 925 x Non Commercial 79A 156 975 156 975 x Commercial Non Commercial in Great Lakes only 80A 157 025 157 025 x Commercial Non Commercial in Great Lakes only 81A 15...

Страница 15: ...ercial and Ship Movement Also used for pilotage purposes 12 156 600 156 600 WC AC GL Inter ship Ship Shore Commercial Non commercial and Ship Movement Port operations and pilot information and message...

Страница 16: ...p Ship Shore and Commercial Commercial fishing only 63A 156 175 156 175 Tow Boats BCC area 64 156 225 160 825 PC Ship Shore and Public Correspondence 64A 156 225 156 225 EC Inter ship Ship Shore and C...

Страница 17: ...25 EC PC Inter ship Ship Shore and Commercial 81A 157 075 157 075 Inter ship and Ship Shore Canadian Coast Guard use only in the St Lawrence River Great Lakes areas 82A 157 125 157 125 Inter ship and...

Страница 18: ...m Squelch Threshold 119 dBm Tight 113 dBm to 107 dBm Rated Audio Output 5 THD Speaker 250 mW Adjacent Channel Rejection 70 dB Image Rejection 70 dB Intermodulation Rejection 68 dB Maximum S N 1 mV 40...

Страница 19: ...any one of the following as we decide i The supplying of the services again ii The cost of having the services supplied again 2 4 For repairs outside the warranty period we warrant our repairs to be f...

Страница 20: ...PN 311032 DN 49418 4 GME Pty Ltd 17 Gibbon Road Winston Hills NSW 2153 Australia gme net au...

Отзывы: