6
O P E R AT I N G M A N U A L
B C M 0 0 2
OPERATIONAL TEMPERATURE GUIDE
• The BCM002 is to be operated in ambient temperatures of less than 40 ˚C
• The following table provides the approximate maximum temperature the
BCM002 will reach when charging 6 x flat battery packs over a 4.5-hour period
• The table also shows the resting temperature of 6 x fully charged battery packs
stored in the BCM002.
Ambient Room
Temperature
BCM002 Charging Max
Operational Temperature*
BCM002 Resting
Temperature
20˚C - 25˚C
35˚C -40˚C
25˚C- 30˚C
25˚C - 35˚C
40˚C - 45˚C
30˚C - 35˚C
35˚C - 40˚C
45˚C- 50˚C
40˚C - 45˚C
*Note:
If the BCM0002 exceeds the operational temperature of 55 ˚C the BCM002
will stop charging and will re-commence charging once at a safe operational
temperature.
TROUBLE SHOOTING
Issue
Indicator
Solution
No Power
LED does not
illuminate
RED
for 2
seconds
Ensure Power Cord is firmly
connected to power socket
and turned on
Battery Not Recognized
LCD screen remains
“INSERT BATTERY”
Ensure a compatible radio/
battery pack is inserted:
See Compatible Radios &
Batteries
Ensure battery pack
terminals on back of battery
pack are clean.
Battery Not Charging
LED Flashes
RED
Battery pack is damaged
resulting in no or low
voltage. Battery pack is to be
replaced.
For faults, warranty claims or replacement battery packs, please contact your