background image

6  

O P E R AT I N G   M A N U A L  

 

B C M 0 0 2

OPERATIONAL TEMPERATURE GUIDE

  • The BCM002 is to be operated in ambient temperatures of less than 40 ˚C  

  •  The following table provides the approximate maximum temperature the 

BCM002 will reach when charging 6 x flat battery packs over a 4.5-hour period 

  •  The table also shows the resting temperature of 6 x fully charged battery packs 

stored in the BCM002.

Ambient Room 
Temperature

BCM002 Charging Max  
Operational Temperature*

BCM002 Resting 
Temperature

20˚C - 25˚C

35˚C -40˚C

25˚C- 30˚C

25˚C - 35˚C

40˚C - 45˚C

30˚C - 35˚C

35˚C - 40˚C

45˚C- 50˚C

40˚C - 45˚C

*Note:

  If the BCM0002 exceeds the operational temperature of 55 ˚C the BCM002 

will stop charging and will re-commence charging once at a safe operational 
temperature.

TROUBLE SHOOTING

Issue

Indicator 

Solution 

No Power 

LED does not 

illuminate 

RED

 for 2 

seconds

Ensure Power Cord is firmly 
connected to power socket 
and turned on

Battery Not Recognized

LCD screen remains  

“INSERT BATTERY”

Ensure a compatible radio/
battery pack is inserted:

See Compatible Radios & 
Batteries

Ensure battery pack 
terminals on back of battery 
pack are clean.

Battery Not Charging 

LED Flashes 

RED

Battery pack is damaged 
resulting in no or low 
voltage. Battery pack is to be 
replaced.

For faults, warranty claims or replacement battery packs, please contact your 
Authorised GME Commercial dealer or Authroised GME Reseller. 

Содержание BCM002

Страница 1: ...OPERATING MANUAL BCM002 6 Bay Multi Charger to suit CP40 CP50 TX6600PRO TX6600S...

Страница 2: ...OX 3 COMPATIBLE RADIOS BATTERIES 3 GENERAL SAFETY OPERATIONAL INSTRUCTIONS 3 OTHER KEY SAFETY AND OPERATIONAL INFORMATION 3 QUICK START GUIDE 4 LCD MENU GUIDE 5 OPERATIONAL TEMPERATURE GUIDE 6 TROUBLE...

Страница 3: ...lated and dry space aAt least 10 centimetres 4 inches distance between the BCM002 and all walls aAway from foot traffic The BCM002 is not to be operated Outdoors or exposed to direct sunlight During s...

Страница 4: ...current capacity Charger Output Electric current maximum 1000mA 5 DC per station 2 Flip the power switch to AC or DC Power DC OFF AC All empty BCM002 pockets will turn RED for 2 seconds to indicate t...

Страница 5: ...e in approximately 4 5 hours LED of the pocket with a fully charged battery will turn GREEN LCD will display BATTERY FULL LCD MENU GUIDE BCM002 Charger Pocket Status LCD Display LED Colour Status Powe...

Страница 6: ...CM0002 exceeds the operational temperature of 55 C the BCM002 will stop charging and will re commence charging once at a safe operational temperature TROUBLE SHOOTING Issue Indicator Solution No Power...

Страница 7: ...re satisfied are defective We warrant any replacement parts for the remainder of the period of warranty for the goods into which they are incorporated 2 3 To the extent permitted by law our sole liabi...

Страница 8: ...quest rma gme net au 2 8 If we determine that your goods are defective we will pay for the cost of returning the repaired or replaced goods to you and reimburse you for your reasonable expenses of sen...

Отзывы: