GMDE Powervortex 306KTL
Global Mainstream Dynamic Energy Technology Ltd.
18
regulations must be observed!
4. Mount the device at an appropriate distance from combustible materials.
5. We recommend that you mount the device at eye level to ensure optimum user comfort.
6. Owing to its protection type (IP65), the device can also be mounted in outside areas.
Figure 9 Installation patterns
3.3.2 Mounting the Inverter
There are only two steps to mount the inverter. The first step is fixing the wall bracket and the second
step is mounting the inverter. All the steps are shown below by the form of illustration.
The wall bracket can be fixed to the wall by four expansion bolts (M8*12mm: thread diameter is 8mm,
nominal diameter is 12mm). Select the appropriate screw types and dimensions for the wall material
is very important.
Inverter weight and dimensions are listed as follows:
Description
Powervortex
306KTL
3-phase Transformerless Grid-tied Hybrid Inverter (maximum PV power: 6kW;
maximum battery power: 6kW; Maximum output power: 6kW)
Dimension
670mm x 540mm x 290mm
Weight
48 kg
Table 3 Information of GMDE Powervortex 306KTL