background image

AC 100T

SAFETY

05/10

2

Designated use

The AC 100T is to be used exclusively for crimping wire-end ferrules with cross sections between 4
and 10 mm². Under no circumstances should large metal parts or similar objects be introduced, the
die set will be ruined.

Unauthorised amendments to the AC 100T are prohibited for safety reasons!

!

Observation of all instructions and compliance with the prescribed operating
conditions are part of the designated use.

Sources of danger

The AC 100T must only be operated when the finger guard plate is screwed on.

Only filtered compressed air with a maximum pressure of 6 bar can be used.

Disconnect the machine from the compressed air before working on the AC 100T, during breaks and
when the device is not in use. Do

not

pull on the compressed air tubing to disconnect.

Work places

The following should be avoided for operation and storage:

damp or dusty places,

places which are subject to high levels of heat, direct sunlight or low temperatures (operating
range: 15 °C to 35 °C).

Protect the compressed air tubing from heat, oil and sharp edges.

Safety devices

The AC 100T has a finger guard plate at the front as a contact safety device.

Under no circumstances should this be removed.

The AC 100T is stopped when disconnected from the compressed air supply.

Permitted operators

Only authorised and instructed operators can work on the AC 100T.

The operator is responsible to third parties in the working area.

The owner must

make the operating instructions available to the operator and

make sure that the operator has read and understood them.

Guarantee

Содержание AC 100T

Страница 1: ...AC 100T Operating instructions Pneumatic Crimper AC 100T Date of issue 05 2010 Keep for future use...

Страница 2: ......

Страница 3: ...ssible accident or injury hazard and or possible damage to the AC 100T Indicates notes on application Dangerousness of the machine The AC 100T has been constructed according to recognised technical sa...

Страница 4: ...AC 100T during breaks and when the device is not in use Do not pull on the compressed air tubing to disconnect Work places The following should be avoided for operation and storage damp or dusty plac...

Страница 5: ...personnel or property are inadmissible if the following points have been violated Non designated use of the AC 100T Inappropriate working places Inappropriate use and use which goes beyond that descri...

Страница 6: ...etop unit and a foot operated switch As both hands are free to insert the wire with fitted wire end ferrules the AC 100T is ideally suited to pre confectioning cables Components 1 Tabletop unit 2 Comp...

Страница 7: ...the tabletop unit and screw tightly to the worktable Check the compressed air supply min 4 bar max 6 bar filtered air Connect the free connection 5 on the foot switch to the compressed air supply Oper...

Страница 8: ...ightly oil pivot 4 Push in die set 5 Tighten hexagon socket screw 6 Lubrication Unscrew the head 1 Remove the spring 2 and piston 3 Lubricate the two arms of the die set 4 e g Gleitmo 746 Insert pisto...

Страница 9: ...6 Spare parts No Part Article No No Part Article No 1 Compressed air tubing 2534 9 Head section 10005 2 Tabletop unit complete 10060 10 Pivot pin 2503 3 Body 2531 11 Die set 10001 4 Adhesive rubber pa...

Страница 10: ...4 10 mm Compressed air connection min 4 bar max 6 bar Air consumption 0 2 l Crimping at 5 bar Dimensions diameter x length x height 200 x 135 x 75 mm Weight approx 1 000 g Name plate Type Crimping ran...

Страница 11: ...n and construction as well as the equipment that we have introduced onto the market This declaration is rendered invalid in the case of amendments to the machine that have not been authorised by our c...

Страница 12: ...sslegg Germany Tel 00 49 0 7563 9123 0 Fax 00 49 0 7563 9123 99 The company GLW retains the copyright to these operating instructions It is not permitted to reprint reproduce or translate even excerpt...

Отзывы: