Motional parameters (PARAMETER)
* Note:
A renewed teach-in procedure
(Teach) is required.
Parameter Description
Setting range
Default
Vo
Opening speed (velocity open)
0...14 (5...50°/s)
6
Vc
Closing speed (velocity close)
0...14 (5...50°/s)
4
TOEx
Hold-open time opening element inside/outside (time hold opening element inside/outside)
0...60 s
3 s
TKey
Hold-open time Key (time hold opening element Key)
0...180 s
5 s
Obst
Adjustable obstacle detection
Upon reaching the adjusted number of obstacles in sequence, the drive mechanism switches to manual
operation.
1...5
5
TDelay
Starting delay (time delay lock)
0,0...4,0 s
0,2 s
FDelay
Relieving force during unlocking (force delay)
only effective if TDelay is > 0
0,0...7,0 A
OFF
TLock
Door rectification time (time press close)
0,0...4,0 s
0,5 s
FLock
Pressing force during locking (force lock)
only effective if TLock is > 0
0,0...7,0 A
2,0 A
FSlam
Accelerating function in automatic mode (force slam)
0...10
OFF
FWind
Obstacle detection optimized for exterior doors (force wind)
OFF
OPEN
CLOSE
BOTH
OFF
Fo
Opening force (force open)
0...9
4
Fc
Closing force (force close)
0...9
4
Foh
Hold-open force (force open hold)
0...9
0
Fch
Interlocking force (force close hold)
automatically programs FLock and FDelay if these are 0
0,0...3,5 A
0
LowEn
Low-energy operation (Low-Energy)
according to EN16005
OFF
BOTH
CLOSE
OPEN
OFF
Width
Width door leaf to be adjusted
only if LowEn is active
90...160 cm
100 cm
Weight
Weight door leaf to be adjusted
only if LowEn is active
50...250 kg
100 kg
Ao
Door leaf opening angle (angle open)
If the opening angle is changed during the operating mode OPEN, the operating mode MANUAL needs to be
selected for closing the door.
20...(190°)
Rod depending
95°
*
Rod
Type of rod assembly (Rod)
Lintel mounting
Normal rods pushing function
Sliding rods pulling function
Sliding rods pushing function
Leaf mounting
Sliding rods pushing function
Sliding rods pulling function
Normal rods pushing function
Direct drive
pushing function
pulling function
STD-PH
SLI-PL
SLI-PH
WIN-PH
WIN-PL
WIN-ST
DIR-PH
DIR-PL
STD-PH
*
Invers
Inverse application
In the event of a power failure/error, the door leaf is opened by spring power from any position (unless it has
not been locked). The position of the motor connector is reversed with regard to the standard drive mecha
-
nism. The electric lock/holding magnet must be connected in reverse order in comparison to the standard
drive mechanism (see wiring diagram E4-0141-713_Glutz).
OFF
ON
OFF
*
dAxis
Distance between rotation axis of the door hinges and the mounting level of the drive mechanism (distance
Axis).
dAxis is an approximate value. Depending on the installation situation, dAxis may have to be adapted.
-8...+25 cm
Rod depending
0/+8 cm
Rod depend.
*
Fos
Limitation of the opening force
Must not be increased in Germany!
5...14 A
5 A
FTic
Closing force in closed position before Teach
only visible if Invers is ON
5...14 A
5 A
Mounting plate
Содержание SD-L F 9365 Series
Страница 88: ......
Страница 89: ......
Страница 90: ......
Страница 91: ......
Страница 92: ......
Страница 93: ......
Страница 94: ......
Страница 95: ......
Страница 96: ......
Страница 97: ......
Страница 98: ......
Страница 99: ......
Страница 100: ......
Страница 101: ......
Страница 102: ......
Страница 103: ......
Страница 104: ......
Страница 105: ......
Страница 106: ......
Страница 107: ......
Страница 108: ......
Страница 109: ......
Страница 110: ......
Страница 111: ......
Страница 112: ......