FR10 Bar Quick Start and Safety Manual Rev. A
6.
AC mains power
Warning!
Read ‘Safety’ starting on page 4 for important safety information
that you must understand before you install or operate the fixture.
Check that all cables and connectors are suitable for the installation
environment and application (see recommendations in ‘Avoiding damage to the
fixture’ on page 9).
Use minimum 14 AWG or 1.5 mm2 power input and relay cables that are minimum 16
A-rated and temperature-rated to suit the application. In the USA and Canada the
cables must be UL-listed, type SJT or equivalent. In the EU the cables must be type
H05VV-F or equivalent.
Power cable
The FR 10 Bar is supplied with a power cord with a Neutrik powerCON TRUE1 connector
for AC mains power input.
Connecting to power
The AC mains power supply must include a connection to ground / protective earth. It
must be protected against ground / earth leakage and overload. The fixture’s internal
auto-sensing power supply accepts AC power at 100-240 V, 50/60 Hz. Do not connect
the fixture to power at any other voltage or to an external dimmer.
The FR 10 Bar does not have a power ON/OFF switch. Power is applied to the fixture as
soon as the power cable becomes live.
The FR 10 Bar has a 3-conductor Neutrik powerCON TRUE1 Mains IN power input socket
that accepts AC power from a TRUE1 female cable connector. Although TRUE1
connectors support hot-plugging, it is still good practice to shut down power to power
cables before connecting them to fixtures.
To connect the fixture to power:
If possible, shut down power to the power input cable.
Note the position of the keys and keyways on the TRUE1 power cable connector
and Mains IN socket and align them with each other carefully. Insert the cable
connector into the socket and twist clockwise to lock. Do not use force. If the
connector feels excessively stiff, remove it and check that it is lined up correctly.
Before applying power to the power cable, check that nobody is looking directly
into the front of the fixture and check that there is no risk of collision if the head tilts
without warning.
To disconnect the fixture from power, pull the latch on the cable connector outwards
to release it, then twist the connector counterclockwise and pull to remove it from the
socket.