background image

 

W

W

W

W

W

W

C

C

C

 

 

 

&

&

&

 

 

 

C

C

C

C

C

C

W

W

W

 

 

GLP 

 German Light Products GmbH 

(Instruction version 1.14) / from software version 1.00/03)

 

7

 

 

For the various mounting positions of the 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N (standing on the floor, 

sideways  or  hanging)  different  accessories  kits  are  available.  Using  any 

required  kits,  along  with  the  standard mounting  connectors  on  the  base  of the 

fixture, will ensure a safe and firm installation.  

 

1x M10 

(length max.16mm)

2x Camlock
quick release
fasteners

front side of the fixture

 

 

2.1.1  Mounting on the floor (upright) 

To  operate  the 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N  in  an  upright  position,  please  use  the 

dedicated  floor-stand  which  ships  with  all  original  fixtures.  The  floor 

stand  is    mounted  to  the  base  of  the  fixture  using  the  two  Camlock 

quarter turn fasteners. Line up and engage the camlock connectors from 

the floor stand into the base of the fixture and turn the two fasteners 90° 

to lock them. Do the opposite to release them again. On both sides you'll 

find eyelets to pull though a fixing strap. This allows additional bracing of 

the floor-stand during the upright operation.  

Содержание IMPRESSION 120 RZ WWC

Страница 1: ...Instruction Manual W W WW W WC C C C C CC C CW W W from software version 1 00 03 Instruction version 1 14 e mail service glp de Internet http www glp de...

Страница 2: ...systems the I IM MP PR RE ES SS SI IO ON N 1 12 20 0 R RZ Z W WW WC C as well as the I IM MP PR RE ES SS SI IO ON N 1 12 20 0 R RZ Z C CC CW W The two systems differ from each other only by the number...

Страница 3: ...2 1 1 Mounting on the floor upright 7 2 1 2 Mounting in hanging position head down 8 2 1 3 Mounting in a sideway position 8 2 2 Securing the Device 9 2 3 Connections 9 2 3 1 Power Supply 9 2 3 2 DMX 1...

Страница 4: ...1 Moving head actively and passively cooled 2 Arm with various cooling vents 3 LCD Display Menu data entry 4 Base with various connectors and Camlock mounting system 1 2 3 4 5 base side 1 6 base side...

Страница 5: ...able parts Opening the fixture will void the manufacturers warranty 6 Danger of burning Wait at least 15 minutes after disconnecting the AC power before changing the optical carrier on the fixture Pay...

Страница 6: ...entioned in this manual 11 Use only original spare parts Any structural modification on the system will terminate all warranty claims 12 Please keep this instruction manual for future reference 2 Prep...

Страница 7: ...quick release fasteners front side of the fixture 2 1 1 Mounting on the floor upright To operate the I IM MP PR RE ES SS SI IO ON N in an upright position please use the dedicated floor stand which sh...

Страница 8: ...To operate the I IM MP PR RE ES SS SI IO ON N in a sideways position please use an additional mounting bar available from GLP or one of their agents This mounting bar is fixed via the two camlock quic...

Страница 9: ...can be attached to the fixture by threading it through one of the two holes provided on the base of the fixture Ensure that the safety wire is securely fastened through the fixture and the fixtures mo...

Страница 10: ...Manual DMX Manual control of all system functions Pan Manual control for Pan X movement Speed Movements Speed adjustment for Pan Tilt movements see also item below Pan Tilt Movements Manual control fo...

Страница 11: ...MX Image Stores the Scene currently sent to the unit DOWN UP DMX input Monitor Indicates the presently received DMX signal per DMX channel Pan Instantaneous value for Pan Speed Movements Speed adjustm...

Страница 12: ...the system 0 100 0 255 00 FF 0 100 7 Shutter Shutter closed 0 15 00 0F 0 5 5 Random Pulse effect slow fast 16 47 10 2F 6 18 5 Up dimming then Shutter closing random patterns slow fast 48 79 30 4F 19...

Страница 13: ...de 9 DMX channels Channel Function Time and Value DMX HEX 1 PAN coarse 0 660 3 2 s 0 255 00 FF 0 100 2 PAN fine High Pos High Pos 2 6 16 Bit 0 255 00 FF 0 100 3 Tilt coarse 0 300 1 5 s 0 255 00 FF 0 1...

Страница 14: ...79 30 4F 19 31 5 Shutter open then down dimming random patterns slow fast 80 111 50 6F 32 43 Up dimming then down dimming random patterns slow fast 112 143 70 8F 44 56 Strobe effect pause 5s to 1s 14...

Страница 15: ...hat the fixture is kept clean and that dust dirt and smoke fluid residues must not build up on or within the fixture If they do the fixture s light output will be significantly reduced and damages to...

Страница 16: ...ted overheating switch Mounting Position Any see chapter mounting Lighting System Additive Color mixing LED Type 120x Rebel High power LEDs Lifetime 50 000 h CCW version 78x LEDs cold white 42x LEDs w...

Страница 17: ...lamps 8 I Instruction Version 1 Internet 1 L LED Class 2M 5 M Maintenance 15 Menu Field 10 Micro fuse 9 Mode key 10 Mounting 6 Mounting in hanging Position 8 Mounting in sidewise Position 8 Mounting o...

Страница 18: ...W W WW W WC C C C C CC C CW W W GLP German Light Products GmbH Instruction version 1 14 from software version 1 00 03 18...

Отзывы: