10
2000225231B
3 Water Systems
Diagram 3.2
Diagram 3.3
0090M
1m MIN.
27m Max.
PUMP
HEATING
SYSTEM
INDIRECT
CYLINDER
(Shown with
recommended
thermostat and valve).
22mm VENT
15mm COLD FEED
REFER TO BS 5546
28mm
VIEWED
FROM
FRONT
6455
FEED AND
EXPANSION
CISTERN
22mm VENT
(MIN.)
15mm (MINIMUM)
COLD FEED
OPEN VENTED FULLY PUMPED WATER SYSTEM
RECOMMENDED RELATIONSHIP BETWEEN
PUMP COLD FEED AND VENT
450mm
MIN.
HEIGHT
1150mm
MIN.
RETURN
FLOW
CYLINDER
PUMP
HEATING
150mm
MAX.
BOILER
IF REQUIRED
15mm (MINIMUM)
BY-PASS WITH
LOCKSHIELD VALVE
FLOW
RET.
There must always
be a cold water path
to the return
connection
of the boiler.
PUMPED
RETURN
PUMPED
FLOW
4124
Diagram 3.4
1metre Min.
27 metres
Max.
22mm VENT & 15mm COLD FEED
TO BE FITTED IN ACCORDANCE
WITH BS 5449
INDIRECT
CYLINDER
ALTERNATIVE
SYSTEM
CONTROL
VALVES
HEATING
SYSTEM
PUMP
FULLY PUMPED CIRCULATION
SYSTEM (DIAGRAMMATIC)
6461
IF REQUIRED
BYPASS 15mm
MIN WITH
LOCKSHIELD
VALVE
22mm
PIPE
RETURN
FLOW
4107
1metre Min.
27 metres
Max.
22mm FOR COMBINED FEED & VENT
TO BE FITTED IN ACCORDANCE
WITH BS 5449
INDIRECT
CYLINDER
ALTERNATIVE
SYSTEM
CONTROL
VALVES
HEATING
SYSTEM
PUMP
FULLY PUMPED CIRCULATION
BYPASS (DIAGRAMMATIC)
6456
IF REQUIRED
BYPASS 15mm
MIN WITH
LOCKSHIELD
VALVE