7.1 Flue Length
For a rear flue, measure the distance from the outside wall face to
the boiler mounting wall. Check that the flue length will be suitable,
see diagram 3.1 for a standard flue system or diagram 3.3 for a 2
or 3metre flue system.
For a side flue, measure the distance from the outside wall face to
the side of the boiler mounting frame. Check that the flue length will
be suitable, see diagram 3.2 for a standard flue system or diagram
3.4 for a 2 or 3metre flue system.
7.2 Rear Flue
Note. Do not cut the flue duct at the pre-drilled end.
Mark the air duct/terminal assembly and the flue duct at the lengths
shown in diagram 7.1 then cut to length, cutting square and
removing any burrs.
7.3 Side Flue
Note. Do not cut the flue duct at the pre-drilled end.
Mark the air duct/ terminal assembly and the flue duct at the lengths
shown in diagram 7.2 then cut to length, cutting square and
removing any burrs.
7.4 Flue Assembly
Locate the flue duct, drilled end, onto the flue elbow and secure with
screw supplied in loose items pack, see diagram 7.3.
Slide the spacer onto the flue duct.
Locate the flue duct/elbow into the air duct/terminal spigot and the
air duct/terminal into the flue elbow making sure of the correct
alignment of top. Drill the air duct and secure/seal (external fixing,
do not seal) as shown in diagram 7.3.
7.5 Wall Liner
If a wall liner is used, fit self adhesive seal as follows:
For wall thickness up to 300mm fit the self adhesive seal to the air
duct, see diagram 7.5, make sure the joint is on top.
For wall thickness over 300mm see diagram 7.4.
7 Flue Preparation
Diagram 7.2
OUTSIDE
WALL FACE
"Y"
Diagram 7.1
BOILER
MOUNTING
WALL
"X"
SIDE OF
BOILER
MOUNTING
FRAME
OUTSIDE
WALL
FACE
Diagram 7.3
FLUE ELBOW
FLUE DUCT
SECURING
SCREW (1)
AIR DUCT/
TERMINAL
SEALING TAPE
3mm Drill
FLUE DUCT/
ELBOW
FLUE
SPACER
"Y" plus 182
(FLUE DUCT,
AIR DUCT/
TERMINAL
ASSEMBLY)
"X" plus 120
(FLUE DUCT,
AIR DUCT/TERMINAL ASSEMBLY)
6386
6470
6471