Supplied By www.heating spares.co Tel. 0161 620 6677
29
221045A
4 R e p l a c e m e n t o f P a r t s
4.32 Clock/Timer - if fitted
Digital clock/timer - Style 1 - Release the mounting
bracket securing screws, see diagram 4.26.
Disconnect the electrical cables, squeeze the retaining
tabs to release the clock/timer, see diagram 4.26.
Electro/mechanical and Digital clock/timer - Style 2 -
Release the mounting bracket securing screws, see
diagram 4.26.
Disconnect electrical cables, release securing clip to
remove the clock/timer and spacer, see diagram 4.27.
Diagram 4.26
KEY
br BROWN
b BLUE
p PURPLE
SECURING
SCREWS (2)
ELECTRICAL
CONNECTIONS
MAINS
NEUTRAL (N)
MAINS
LIVE (L)
HEATING ON
COMMON
RETAINING
TABS (4)
p p br b
4609
SECURING CLIP (2)
SPACER
MOUNTING
BRACKET
Diagram 4.27
TIMER/CLOCK
4777
CLOCK/TIMER
DIGITAL CLOCK/TIMER STYLE 1
ILLUSTRATED
ELECTRO/MECHANICAL and
DIGITAL CLOCK/ TIMER
STYLE 2 ILLUSTRATED