Supplied By www.heating spares.co Tel. 0161 620 6677
20
221045A
p
4 R e p l a c e m e n t o f P a r t s
Diagram 4.9
Diagram 4.10
4.14 Transformer
Note. Timer/clock may be removed to improve access,
see Section 4.32 or the control housing bottom half can
be removed.
Remove the control housing cover screw, see
diagram 4.8.
Remove control housing assembly, see diagram 4.1.
Remove the control housing cover and disconnect the
electrical connectors from the transformer, see
diagram 4.8.
Remove the transformer securing screws (2 off) from
beneath the control housing, remove the transformer and
insulation.
To connect the transformer cables correctly, refer to
diagram 4.11.
FAN DRIVER
BOARD
FAN DRIVER
CONTROL
HOUSING
SECURING
SCREW NUT
SUPPORT
POSTS
MULTI-PIN
CONNECTORS
4596
CLOCK/
TIMER
HEATING ON
240V~50Hz PERMANENT
MAINS SUPPLIED
FUSED AT 3A
b
br
p
r
g/y
b
br
p
b
br
p
b
(N)
(L)
COMMON
KEY
PURPLE
RED
BLUE
BROWN
GREEN/YELLOW
p
r
b
br
g/y
br
g/y
r