6
221129A
❋
HORIZONTAL FORWARDS or BACKWARDS
ELBOW / 2 x 90
o
BENDS
HORIZONTAL and DOWNWARDS
ELBOW / 2 x 45
o
BENDS
ELBOW / 2 x 45
o
BENDS
ELBOW / 2 x 45
o
BENDS
ELBOW / 2 x 90
o
BENDS
234 MIN.
'Y'
'Z'
57
MIN.
168
MIN.
'X'
'Y'
194
MIN.
'X'
'Y'
'X'
'X'
341 MIN.
57
MIN.
'Z'
'Y'
FLUE BEND KIT
FLUE KIT 1m
Part No.448490
Part No.448468
ELBOW/TERMINAL PACK
Part No.438130
2 off
1 off
1 off
MAX. FLUE LENGTH X+Y+Z = 600mm
❋
MAX. FLUE LENGTH X+Y+Z = 1800mm
❋
FLUE BEND KIT
FLUE KIT 2m
ELBOW/TERMINAL PACK
Part No.438130
1 off
1 off
MAX. FLUE LENGTH X+Y = 1800mm
❋
FLUE BEND KIT
FLUE KIT 1m
Part No.448490
Part No.448468
ELBOW/TERMINAL PACK
Part No.438130
2 off
1 off
1 off
MAX. FLUE LENGTH X+Y+Z = 600mm
❋
Diagram 3.5
▲
▲
230
MIN.
194
MIN.
▲
▲
Part No.448468
1 off
Part No.448491
FLUE KIT 1m
1 off
Part No.448490
FLUE BEND KIT
FLUE KIT 2m
ELBOW/TERMINAL PACK
Part No.438130
1 off
1 off
Part No.448468
1 off
Part No.448491
FLUE KIT 1m
1 off
Part No.448490
MAX. FLUE LENGTH X+Y+Z = 1800mm
❋
FLUE BEND KIT
FLUE KIT 2m
ELBOW/TERMINAL PACK
Part No.438130
1 off
1 off
Part No.448468
1 off
Part No.448491
FLUE KIT 1m
1 off
Part No.448490
▲
▲
▲
▲
▲
KEY
= The maximum ‘Flue
Length’ does not include the
elbows.
= Installation clearance
IMPORTANT
For every 45
°
bend used the straight flue
length of 2metres must be decreased by
600mm minimum, this must be taken into
account when measuring the total flue length.
F l u e B e n d K i t
'Z'
'X'
'Y'
398 MIN.
194
MIN.
▲
▲
'X'
'Z'
'Y'
290 MIN.
194
MIN.
▲
▲
3526