Supplied By www.heating spares.co Tel. 0161 620 6677
23
221098C
7 S e r v i c i n g
7.4 Combustion Products Discharge Safety
Device
Remove the burner refer to Section 7.3.
Check the condition of the electrode and thermocouple,
with a soft brush, see diagram 7.8.
Make sure the electrode is in line with the earth post and
spark gap is as in diagram 7.9.
7.5 Ignition Lead
Remove the burner refer to Section 7.3.
Disconnect the union connections, remove the mounting
bracket securing screws and combustion products
discharge safety device, see diagram 7.8.
Check the ignition lead, see diagram 7.8.
Replace if required, refer to Section 9.5.
Note. When refitting the combustion products discharge
safety device, take care not to trap the ignition lead under
the mounting bracket.
7.6 Gas Tap and Micro Switch Assembly
Note: This item need not be serviced annually.
Remove micro switch electrical connections, see
diagram 7.10.
Disconnect all union connections and remove the tubes
in the order shown diagram 7.11.
Disconnect the thermocouple nut, see diagram 7.12.
When replacing only tighten the nut a quarter turn
beyond finger tight.
Remove the gas tap bracket securing screws,
see diagram 7.12.
Remove the gas tap assembly.
To service the gas tap remove the gas tap niting plate
assembly securing screws, see diagram 7.13.
Take care as there is a spring beneath the niting plate.
Remove the plug, pin, spring washer, plain washer and
“O” ring, see diagram 7.13.
Clean and relubricate using a suitable grease.
When replacing make sure the operating disc, with
retaining washer and micro switch and leads are
correctly located, see diagram 7.13 and 7.10.
5075
Diagram 7.7
SECURING
SCREW (2)
SECURING
SCREW (2)
TUBE
NUT
MOUNTING
BRACKET
TUBE
NUT
COMBUSTION PRODUCTS
DISCHARGE SAFETY
DEVICE
TUBE
NUT
IGNITION
LEAD
5075