1 G e n e r a l
Sheet Metal Parts
WARNING. When installing or servicing this fire front
care should be taken when handling metal parts
(components), to avoid any possibility of personal
injury.
1.2 Statutory Requirements
The installation of this fire front must be carried out by a
competent person, in accordance with the current issue
and relevant requirements of:-
Manufacturer’s instructions, supplied.
The Gas Safety (Installation and Use) Regulations, as
amended, The Building Regulations, the Local Gas
Undertaking, The Building Standards (Scotland)
Regulations (applicable in Scotland), The Health and
Safety at Work Act, Control of Substances Hazardous to
Health, The Electricity at Work Regulations and any
applicable local regulations.
Detailed recommendations are contained in the current
issue of the following British Standards and Codes of
Practice:-
BS1251, BS5440 Part 1 and 2, BS5871, BS6891,
BS7671.
Manufacturer’s notes must not be taken as overriding
statutory requirements.
CE Mark
The CE mark on this appliance shows compliance with:-
1. Directive 90/396/EEC on the approximation of the
Laws of the Member States relating to appliances
burning gaseous fuels.
2. Directive 89/336/EEC on the approximation of the
Laws of the Member States relating to electromagnetic
compatibility.
If this fire front is to be fitted to a Glow-worm back
boiler WITHOUT a combustion products discharge
safety device please read the supplementary instructions
at the back of this booklet.
The instructions consist of three parts, Installation and
Servicing Instructions for the Back Boiler Unit,
Installation and Servicing Instructions for the Fire Front
and Instructions for Use, including the Guarantee
Registration Card. The instructions are an integral part
of the appliance and must, to comply with the current
issue of the Gas Safety (Installation and Use)
Regulations, be handed to the user on completion of the
installation.
1 General Notes and Information
This Glow-worm gas fire front is to be used with a
specially designed Glow-worm Back Boiler Unit only.
This fire front and back boiler are NOT suitable for
fitting to a precast flue.
The fire front is delivered packed in two cardboard
cartons, which together contain all the parts necessary
for the installation of the fire front.
If the back boiler and fire front are to be installed at the
same time please read both sets of installation
instructions before starting.
Wherever possible, all materials, appliances and
components to be used shall comply with the
requirements of applicable British Standards.
Where no British Standards exist, materials and
equipment should be fit for their purpose and of suitable
quality and workmanship.
1.1 Important Notice
This fire front is for use only on G20 gas.
This fire front is fitted with a safety device which will
shut it down if there is a lack of oxygen. If the fire shuts
down frequently for no apparent reason the first things to
be checked are the chimney and the air inlets into the
room. An additional cause could be that the filter, in the
gas tap has become blocked. Any problems found must
be put right, by a competent person, before the fire is
used again.