24
221899A
10 Replacement of Parts
10.12 Fan, Part No. 227033 - diagram 10.7
Refer to Section 5.3.
If top outlet installation: Remove air deflector, or it may just be
swung back by loosening the securing screws, to enable fan
assembly to be removed, see diagram 8.7 and Section 5.3.
Remove the electrical connections and disconnect the air tube.
Note: Remove the electrical connections by pulling insulation
boots only.
Remove the fan assembly securing screw at the front, then
withdraw the assembly.
The fan is secured to the flue hood by three screws.
The polarity of the electrical connections is not important.
Diagram 10.6
CLEAR
AIR TUBE
SECURING
SCREW (2)
AIR
PRESSURE
SWITCH
ELECTRICAL
CONNECTIONS
7227
Diagram 10.7
SECURING
SCREW
FAN
ASSEMBLY
ELECTRICAL
CONNECTIONS
FAN
SECURING
SCREW (3)
7165
CLEAR
AIR TUBE
11.1 Part Identification
The part number and the diagram location will help to identify the part.
11.2 Ordering
When ordering any spare parts please quote the number and description from the list together with the model name and serial number.
If ordering from the local gas undertaking also quote the GC number of the appliance and part.
11 Spare Parts
Part No
Description
Location
GC Part No
801159
Multifunctional control - 40FF
Diagram 10.4.
E24851
227033
Fan - 40FF
Diagram 10.7.
E24884
227032
Air pressure switch
Diagram 10.6.
E24881
227057
Electrical thermistor
Diagram 10.1 & 10.2.
E24871
202635
Spark electrode - 40FF
Diagram 8.6.
E24837
204697
Control knob
Diagram 10.3.
E24870
205757
Injector - 40FF
Diagram 8.5.
E24960
227098
Fuse
Diagram 10.3.
*******
227030
Control board - 40FF
Diagram 10.3.
E24877
227038
Safety temperature limiter
Diagram 10.2.
E24897
Because of our constant endeavour for improvement details may vary slightly from those in the instructions.
IMPORTANT:
REMOVE ELECTRICAL CONNECTIONS
BY GRIPPING THE BOOT ONLY