20
Installation/Operation & Maintenance Manual
GM
-
6150H 2-POST LIFT
◆
Close the drain plug.
◆
Fill the power unit with oil throng the plug
located at the top of the power unit reservoir.
The oil must be filtered:
◆
Oil characteristics and types are reported in the
technical specifications
(Chapter 2, page 3)
◆
Close the filler plug
◆
Energize the lift rack
◆
Go through two or three up-down cycles (for a
height about 20-30 centimeters) to insert oil into
the circuit.
When changing the oil:
use only recommend oil or
the equivalent; do not use deteriorated oil that has
been in the warehouse for an extended period of
time. Oil should be disposed as indicated in
Appendix A
,
Page 21
.
AFTER EACH MAINTENANCE OPERATION, THE
MACHINE MUST RETURN TO ITS INITIAL
C O N D I T I O N S ,
I N C L U D I N G
T H E
DISASSEMBLEED PROTECTION AND SAFETY
DEVICE.
To ensure good maintenance, it is important:
◆
To sue only tools that are suitable for the job
and original spare parts
◆
Follow the minimum maintenance schedule as
indicated
◆
Immediately find the cause of any abnormalities
(excessive noise, overheating, leaking fluids,
etc)
◆
Pay special attention to lifting parts (cylinders)
and safety devices
◆
Use all the documentation supplied by the
manufacturer (wiring diagrams, etc)
6.3 PERIODIC LUBRIFICATION CHART
Lubricate the rack as indicated in
Fig. 40
. Grease
must be taken from perfectly closed tins and/or well
preserved. Old or damaged grease may damage the
lubricated part.
△
Lubricate every three months
□
Lubricate every six months
Fig. 40