9.3 SOFTWARE UPDATE BY FLASH USB
The SD card must be inserted into the USB port
located on the control unit front side.
The USB memory used for updating must be for-
matted in FAT32, cluster size 4096 bytes (4k).
It is therefore necessary to copy the provided file
update-XXXXX.hex onto the USB memory, pro-
ceeding as follows:
- Turn on the control unit and press the SAT
SELECT button while BOOT is displayed.
- The message READY FOR UPDATE INSERT
USB KEY will be displayed.
- Insert the USB flash formatted in FAT32 contain-
ing the file update-XXXXX.hex.
- The control unit will check the integrity of the
upgrade file displaying CHECK UPGRADE FILE.
- Wait, the upgrade procedure takes about 30 sec-
onds.
- Once the upgrade is completed, UPGRADE
SUCCESSFUL will be displayed.
- Turn off the control unit and remove the USB
memory.
S
WARNING
In case of repeated failures in the software update
procedure, please contact the GLOMEX Service
Centre.
NOTA:
it is possible to download the necessary
software updating file from the Glomex website
(www.glomex.it) in section “Technical Support -
Download Area”.