4. Connect the power supply cable (10-30 Vdc) to
a free switch for the on-board electronic
devices (min. 5A): connect the positive terminal
to the red cable and the negative terminal to the
black cable. The power supply line must have
cables with a minimum cross section of 2.5
mm
2
with a length up to 4 m, of 4 mm
2
for
longer cables.
S
WARNING
Do not use power supply from secondary circuits.
This could jeopardize the operation of the equip-
ment.
S
WARNING
In order to prevent that current leakage or charge
build-up may damage the electronic components of
the antenna, make sure there is an efficient
grounding system.
S
WARNING
Pay attention not to bend the coaxial cables at a
right angle; the bending angle must always be
higher than 120°.
Fig. 15
Backside of the control unit
From the antenna
To the multiswitch (V9104S2U-
V9104SKEWS2U-V9804S2U-
V9804SKEWS2U-R9804S2U) HH
To the multiswitch (R9804SERS2U) VL
Red
Black
10 ÷ 30 Vdc
Fig. 16