DISASSEMBLY & CLEANING
1. Turn slicer OFF.
2. Turn slice thickness dial clockwise past zero (0) until it stops so the table covers the
knife edge.
3. Unplug the power cord.
4. Remove food chute’s end weight. Hold end weight and unscrew slide rod
(Fig. 12-1). Pull slide rod out of the pivot of end weight.
5. Use the food chute handle to pull the food chute towards you (home position).
6. Remove the food chute release knob that fastens the food chute to the slicer.
7. Use the food chute handle to tilt food chute to the right to the cleaning position
(Fig. 12-2).
BE ALERT. THE NEXT STEP WILL EXPOSE THE KNIFE.
8. Remove knife sharpener. Pull knife sharpener up. Turn knife sharpener clockwise to
align pin on sharpener post with slot on knife sharpener (Fig. 12-3).
9. Remove knife cover by rotating knife cover release knob counterclockwise until it
releases (Fig. 12-4).
NOTE:
NEVER
operate slicer with knife cover removed.
BE ALERT.
Slicer knife edge is exposed. Always be aware of the
placement of your hands/fingers in relationship to the knife.
10.
Remove slice deflector. Slice deflector can be removed by loosening the bottom
screw and sliding slice deflector up to remove from slots (Fig. 12-5).
Place all removable parts in a three compartment sink with warm water and a mild detergent solution; soak,
clean and thoroughly scrub all surfaces using a solution of mild detergent and warm water. Removable parts
include: end weight, slide rod, knife cover, knife sharpener
and slice deflector.
Rinse removable parts with fresh, clean water. Following the instructions on your quaternary sanitizer label,
soak end weight, knife cover, knife sharpener and slice deflector in a proper solution of
quaternary sanitizer
for a minimum of two minutes. Allow these parts to air dry.
BE
ALERT.
Slicer knife is fully exposed. Always be aware of the placement of
your hands/fingers in relationship to the knife.
Cleaning & Sanitizing
Figure 12-1
Figure 12-2
Figure 12-3
Figure 12-5
An important step to kill bacteria is to
allow the parts to air dry before reinstalling!
Figure 12-4