1.  INSTALLATION OF COOKER.

The cooker is ready for use and can be connected to the chimney with the flue pipe.
If possible, connect the flue pipe, keeping it short, straight or slightly at an angle to
the chimney.

Seal the connection (heat resisting fire rope).
When fitting the legs do not drag or push the stove but lift it (the legs could break off).
Connect the external air flow by using a pipe.
 
National or European standards, including local standards and any fire 
regulations must be complied with.
Ensure that there is sufficient air flow before burning wood.
This is particularly important in well insulated houses and those with a mechanical
ventilation system.

To ensure your chimney has the correct measurements it is possible to measure
it. Ask your chimney sweeper for advice.

Before placing the cooker into position check to see if the floor can take the weight.
When in doubt place the stove on a large slab of stone or marble to divide the 
weight.

2.  GENERAL FIRE SAFETY INSTRUCTIONS.

During wood burning, high temperatures are reached make it impossible to  
touch the top, sides or door without using heat resisting gloves.

Children must be made aware of the dangers and kept away for the cooker
when lit.

3.

10.

         Installation and operation manual for Stove model ST-1060g 
    Tested according to German standards: DIN EN 12815, Ö-Standard
15A and 1.+2. BimschvV., CE and Luftreinhalte-Verordnung Switzerland   

.

Содержание Titan ST 1060

Страница 1: ...User s manual Titan Ch Leibfried GmbH An der Bundesstra e 2 49733 Haren Ems Germany Tel 49 0 5932 7334784 info globe fire de...

Страница 2: ...d follow up of given guidelines in the manual The connection of more stoves to one chimney is permitted Approved German tests and CE mark gem Art 15a B VG kleine Norm Tests of the city of M nchen Rege...

Страница 3: ...hot approx 15 30 minutes close the grid Add further wood using 1 2 or 3 logs Make sure the wood has a real glow of flames before doing this to prevent smoke in the room Congratulations with your new G...

Страница 4: ...t be closed The fire can be regulated by the revolving grid and the primary secondary air regulator Do not close the primary secondary air regulator before the wood has burnt to a glow and the flames...

Страница 5: ...s sufficient air flow before burning wood This is particularly important in well insulated houses and those with a mechanical ventilation system To ensure your chimney has the correct measurements it...

Страница 6: ...th the primary secondary regulator Do not close up completely while flames are visible This is to avoid smoke entering the room Stay with the cooker until burning well If the fire has been started wel...

Страница 7: ...ow can be cleaned with a glass cleaner Badly stained glass can be cleaned with a special gel or oven cleaner Never clean the cooker when it is hot Remove the ash between the fire grid so that the grid...

Страница 8: ...your electrician 12 FIRE SAFETY DISTANCES Furniture and flammable wall The distance from the back of the cooker is 20 cm From both sides 60 cm From the glass 80 100 cm Floor A flammable floor carpet...