Globe fire Titan ST 1060 Скачать руководство пользователя страница 4

1.

6.

10.

9.

3.

2.

4.

5.

7.

8.

11.

12.

°

Titan

13.

1.     Leg of cooker                            

2.     Cleaning cover                          

3.     Flue connection pipe

4.     Cooker window

5.     Fire / rotating grid

6.     Door handle

7.     Ash pan

                                                   15.   Cinder guard

 8.    Oven window

 9.    Stove bars

10.   Stove bar holders

11.   Primary / Secondary regulator

12.   Ring plates

13.   Oven regulator

14.   External air flow
        (rear)

 

PARTS

15.

Safety regulations

The user must consult the user’s manual for instructions on operating
and using the cooker.

The cooker has been tested according to German regulations and has
acquired the Bauart 1 test.
This offers the possibility of connecting more than one burner to a 
single chimney.
The chimney sweeper should be consulted about this.

When the cooker is in use the door must be closed.
The fire can be regulated by the revolving grid and the primary /
secondary air regulator.
Do not close the primary / secondary air regulator before the wood has 
burnt to a glow and the flames are no longer visible.

In houses where air supply (necessary for the fire to burn) is taken from
the room, there should be a sufficient supply of fresh air.

The ash door should always remain closed when the fire is burning.
If the door is left open an uncontrollable amount of air is added to
the fire which may prove dangerous as the cooker can become 
overheated.
Parts that are in contact with the fire could buckle or even break.

When the cooker is not used for a longer period of time, close the 
revolving grid and the primary / secondary regulator.
This is to ensure that any ash or smell of burning does not enter the
house.

WARNING:  CHILDREN PLAYING !!!
                     A stove becomes very hot when it is burning !!!

2.

11.

Содержание Titan ST 1060

Страница 1: ...User s manual Titan Ch Leibfried GmbH An der Bundesstra e 2 49733 Haren Ems Germany Tel 49 0 5932 7334784 info globe fire de...

Страница 2: ...d follow up of given guidelines in the manual The connection of more stoves to one chimney is permitted Approved German tests and CE mark gem Art 15a B VG kleine Norm Tests of the city of M nchen Rege...

Страница 3: ...hot approx 15 30 minutes close the grid Add further wood using 1 2 or 3 logs Make sure the wood has a real glow of flames before doing this to prevent smoke in the room Congratulations with your new G...

Страница 4: ...t be closed The fire can be regulated by the revolving grid and the primary secondary air regulator Do not close the primary secondary air regulator before the wood has burnt to a glow and the flames...

Страница 5: ...s sufficient air flow before burning wood This is particularly important in well insulated houses and those with a mechanical ventilation system To ensure your chimney has the correct measurements it...

Страница 6: ...th the primary secondary regulator Do not close up completely while flames are visible This is to avoid smoke entering the room Stay with the cooker until burning well If the fire has been started wel...

Страница 7: ...ow can be cleaned with a glass cleaner Badly stained glass can be cleaned with a special gel or oven cleaner Never clean the cooker when it is hot Remove the ash between the fire grid so that the grid...

Страница 8: ...your electrician 12 FIRE SAFETY DISTANCES Furniture and flammable wall The distance from the back of the cooker is 20 cm From both sides 60 cm From the glass 80 100 cm Floor A flammable floor carpet...

Отзывы: