Operating Specifications
41
Appendix C. Operating Specifications
Note
Requirements for a particular installation site depend on the
user’s needs, location, climate, sun hours, call profile, and the
length of autonomous operation desired. These specifications
need to be determined by the service provider or service
provider’s representative.
Power Specifications
The power supply shall supply nominally 12 V DC. It shall support
a load of up to 30 watts. Under no circumstances shall the output at
the power supply ever drop below 10.5 V DC, even under a full load,
or when switching to a backup battery. The output at the power
supply shall not exceed 15.9 V DC.
Mechanical Specifications
RAU
Antenna
Environmental Specifications
RAU
Table 17. Power specifications
Power source
10.5 to 16.0 VDC, 3 A
Power consumption, RAU
30 Watts maximum
Table 18. Mechanical specifications
Width
21.6 cm (8.5 in.)
Height
25 cm (9.7 in.)
Weight
3.04 kg (6.7 lbs)
Table 19. Antenna
Width
2.54 cm (1 in.) diameter
Height
50 cm (19.8 in.)
Table 20. Environmental specifications
Operating temperature
–30 to +60 degrees C
Storage temperature
–40 to +85 degrees C
Humidity
5 to 95%
Содержание GSP-2800
Страница 1: ......