Inventory
10
Make sure you have all supplies and equipment
Check to see which QUALCOMM kit you are installing. Depending
on the kit purchased, you may need additional items to complete the
installation.
Grounding Accessories
Grounding accessories available from electrical supply companies
are not included in the kit; however, they are required to ground the
RAU and junction box. Quantities required in a typical installation
are shown in Table 4. In addition, the installer should supply the
pole needed to support the RAU.
Note
If fabricating your own 15-meter (50-foot) cable for connecting
the RAU to the junction box, the cable must conform to
specifications given in Appendix B. Specifications for Cables.
Specifications for fabricating cables must be followed to avoid
damage or poor performance of the equipment and to avoid
invalidating your warranty.
Table 5 lists the wires and jacks recommended for use in installing
the interior wiring.
Table 4. Grounding Supplies
Type
Quantity needed
#6 AWG copper primary ground cable
Amount needed depends
on site
#6 AWG (pink) ground lug
1 each
#6 AWG solid copper ground wire used to
ground junction box
0.5 meter (1.6 feet)
Copper C-type compression tap (#6 to #6
wire)
1 each
2.7 to 3 meter (8 to 10 foot) ground rod
1 – length depends on soil
type
Copper clamp, #6 AWG wire to ground
rod, screw type
1 each
Bolts to secure grounding wiring to rod
As needed
Wall mounting brackets and fittings
If needed
RAU to junction box cable (provided by
QUALCOMM or the equivalent cable)
See
Appendix B. Specifications for
Cables
.
As needed. Not to exceed
15 m (50 feet).
Pole for mounting
If needed
Cable ties
As needed
Table 5. Interior wiring
Recommended item
Quantity needed
Standard telco cable
As needed to a maximum
of 182 meters (597 feet)
6-position modular jack, wall mount
(EIA-568 or EIA-520) RJ-11
As needed
Wiring boxes
1 each
Table 4. Grounding Supplies