background image

 

15 

 

Enable/ disable AES128 Encryption 

Command 

Description 

 
 
 

AAT3 A0=[parameter] 

 
[Parameter]:1/0 

1

: Enable AES128 Encryption 

0

: Disable AES128 Encryption 

 

Response: 

ok   

parameter is valid 

invalid_param   

parameter is not valid 

 

Read AES128 Encryption Status 

Command 

Description 

 

AAT3 A0=? 

 
Response 

1

- Enable AES128 Encryption 

0-

 

Disable AES128 Encryption 

 

Set AES128 Encryption 

Command 

Description 

 
 
 

 

AAT3 A1=[parameter] 

 

[Parameter]: AES128 Key in hexadecimal 

character(16 Bytes) 

 

Response: 

ok   

parameter is valid 

invalid_param   

parameter is not valid 

 

Default=

476C6F62616C53617432303136616263 

 

Read AES128 Encryption 

Command 

Description 

AAT3 A1=? 

 
Response: AES128 Key in hexadecimal 

Character 

 

Содержание LoRa LM-110H1

Страница 1: ...ation 16F No 186 Jian 1 st Rd Zhonghe Dist New Taipei City 23553 Taiwan Tel 886 2 8226 3799 Fax 886 2 8226 3899 lora globalsat com tw www globalsat com tw USGlobalSat Incorporated 14740 Yorba Court Ch...

Страница 2: ...TENTS Product Description 3 Product Feature 3 Hardware Specifications 4 Pin Definition 5 Product Size 5 LoRaWAN Configuration 6 MOST Link Configuration 7 Federal Communication Commission Interference...

Страница 3: ...ard LoRaWAN FW and proprietary MOST Link FW in the same module Default as LoRaWAN switch to MOST Link by AT command Share same PCB device design for both LoRaWAN and private RF data communication For...

Страница 4: ...dBm Transmission Media UART UART Baud Rate 57600 bps Parity 8N1 Operation Voltage 3 6 V Current Consumption Receiving 21 mA Transmitting 125 mA Sleeping 5 uA Transmission Distance 1KM 10KM 980 bps Rec...

Страница 5: ...cription 1 GND GND Ground 2 VCC Input 3 0 6 0 V 3 RXD Input UART input 4 TXD Output UART output 5 BZ Output Module s operation status 6 P2 Input Pin2 for switching operation mode 7 P1 Input Pin1 for s...

Страница 6: ...ation Activation by personalization directly ties an end device to a specific network by passing the join request join accept procedure Activating an end device by personalization means that the DevAd...

Страница 7: ...ions setting up under MOST Link Under this protocol the default mode is Disable P0 0 which is the payload data transmission in transparent It only supports command A0 A1 for AES128 encryption function...

Страница 8: ...r is not valid Note 1 In Wake up mode LM 130H1 stays awake and send wake up code i e Normal mode plus with preamble byte while transmitting data 2 In Power saving mode LM 130H1 sleeps all the time Sen...

Страница 9: ...Read LoRa Firmware Version Command Description AAT1 L2 Response Firmware version 16 Bytes Example F 0LR 14 1704191 Set LoRa Group ID Command Description AAT1 L3 parameter Parameter The number of LoRa...

Страница 10: ...15MHz and Tx frequency as 915MHz The command is AAT1 L4 915000 915000 Read Rx Tx Frequency of LoRa Channel Command Description AAT1 L4 Response Rx frequency in KHz Tx frequency in KHz Set Data Rate of...

Страница 11: ...of LoRa Channel s Tx Power Command Description AAT1 L7 parameter Parameter Index of Tx power from 0 to 7 0 5dBm 1 7dBm 2 9dBm 3 11dBm 4 13dBm 5 15dBm 6 17dBm 7 20dBm Default 7 Response ok parameter i...

Страница 12: ...first one responding if the command is valid or not After the payload is sent out it would get the second response 1st Response ok parameter is valid invalid_param parameter is not valid 2nd Response...

Страница 13: ...sponding if the command is valid or not After the payload is sent out it would get the second response 1st Response ok parameters are valid invalid_param parameter is not valid 2nd Response TX_OK payl...

Страница 14: ...get the second response 1st Response ok parameters are valid invalid_param parameter is not valid 2nd Response TX_OK payload is sent out TX_NO_ACK payload is sent out but not get ACK TX_BUSY payload i...

Страница 15: ...ryption Status Command Description AAT3 A0 Response 1 Enable AES128 Encryption 0 Disable AES128 Encryption Set AES128 Encryption Command Description AAT3 A1 parameter Parameter AES128 Key in hexadecim...

Страница 16: ...es number of MOST Link while not getting ACK 0 9 0 disable Default 0 Parameter2 Timeout of getting ACK 1 255 seconds Default 3 Response ok parameter are valid invalid_param one or both parameter are n...

Страница 17: ...tion If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interfe...

Страница 18: ...uct In these circumstances the OEM integrator will be responsible for re evaluating the end product including the transmitter and obtaining a separate FCC authorization End Product Labeling This trans...

Отзывы: