background image

Metis micro user manual v1.6

 

11 

 
Input 2 can be configured with a response time. Response time means the time the input 
has to in alarming state until the alarm is registered (see 6.4 –Input settings). 
 
In addition to normal inputs, the device has a built-in tamper switch that alerts when the 
enclosure is opened. The tamper switch can be disabled with a jumper (see 8 – 
connections) 
 

4.

4.

4.

4.4

4

4

4    Output

Output

Output

Output    

 

 

me

me

me

me

tis

tis

tis

tis

 Micro

 Micro

 Micro

 Micro has a small relay that can be used to control external devices. Maximum load 

for the relay is 24VDC/1A. Jumper 2 selects whether the relay acts as a local alarm 
indicator or remotely controllable (see 8 – Connections).  
 
When the alarm relay function is selected the relay gives a pulse (20s – 9min.) during an 
alarm that can be used to control a siren for example. 
 
When the remote control function is selected the relay can be controlled either via a 
phone call or an SMS (the control commands are described in 7.1- relay control 
commands) 
 
For higher loads please use external relays. It is also recommended to use a diode over the 
coil of the external relay to prevent harmful transients..  
 

Note!  Under any circumstances do not connect 230VAC volta

Note!  Under any circumstances do not connect 230VAC volta

Note!  Under any circumstances do not connect 230VAC volta

Note!  Under any circumstances do not connect 230VAC voltage to the device.

ge to the device.

ge to the device.

ge to the device.

 

 

4.

4.

4.

4.5

5

5

5    Input arming and disarming

Input arming and disarming

Input arming and disarming

Input arming and disarming    

 
Selected inputs can be armed / disarmed with a phone call (see. 6.9 – General settings / 
6.5 – Arming and disarming).  
 
Arming/disarming the device and relay controlling via phone call cannot be both used at 
the same time. Please review settings to prevent the double function. 
 
me

me

me

me

tis

tis

tis

tis

 Micro 

 Micro 

 Micro 

 Micro can be armed / disarmed by calling the device from a number that is stored in 

the device’s phonebook (see 5 – Phone numbers). During the call no voice channel is 
opened, only the number is recognized. It is recommended to activate the 
armed/disarmed state reporting to receive an SMS every time the state is changed (see 6.9 
– General settings).  

Содержание metis Micro

Страница 1: ...metis M M M Micro icro icro icro GSM ALARM TRANSMISSION AND CONTROL DEVICE INSTALLATION AND USER MANUAL V1 6 Global Safety Security Solutions Oy www globalsafety fi ...

Страница 2: ...n Operation 12 12 12 12 5 1 Phone numbers 12 5 2 Alarms 12 5 3 Entry exit delay and response times 12 5 4 Backup call 13 5 5 Lock up 13 6 6 6 6 Settings Settings Settings Settings 14 14 14 14 6 1 Language setting 14 6 2 Alarm messages 14 6 3 Phone numbers 15 6 3 1 Storing numbers with a phone call 15 6 3 2 Storing and editing phone numbers with SMS 15 6 4 Input settings 16 6 5 Inputs that follow a...

Страница 3: ... IR detectors a temperature detector etc The device can also be remotely controlled to for example turn on or off heating or lighting 1 1 1 1 1 1 1 1 1 1 1 1 Alarm information Alarm information Alarm information Alarm information Alarm alarm settled from inputs Armed disarmed information Tamper switch alarm alarm settled 1 1 2 1 1 2 1 1 2 1 1 2 Rel Rel Rel Relay ay ay ay Relay control via SMS on o...

Страница 4: ...tallation company ons can only be done by an authorized installation company 1 2 1 2 1 2 1 2 Technical specification Technical specification Technical specification Technical specification Type me me me metis tis tis tis Micro Micro Micro Micro Version This manual applies to v 1 0 GSM SimCom SIM300 900 1800 1900 tri band GSM Connectors 2 digital inputs 1 output relay Enclosure water resistant 130 ...

Страница 5: ...lure has been caused because the device has been influenced by events out of the control of GSSS including but not limited to deficiencies in consumer goods that have limited operating time such as batteries or damages of antennas N N N NOTE This device is not allowed to be used in any other purpose or application than it is OTE This device is not allowed to be used in any other purpose or applica...

Страница 6: ...ng messages after factory set limits This is designed to prevent for example a broken detector causing unlimited number of alarms Note Note Note Note In no circumstances the device is allowed to be conn In no circumstances the device is allowed to be conn In no circumstances the device is allowed to be conn In no circumstances the device is allowed to be connected to 230VAC voltage ected to 230VAC...

Страница 7: ...aditional 9600bps data data means traditional 9600bps data data means traditional 9600bps data data means traditional 9600bps data service service service service CSD CSD CSD CSD For more information contact your service provider For more information contact your service provider For more information contact your service provider For more information contact your service provider The SIM card must...

Страница 8: ...shing the metal clamp gently according to the pictre and lifting the holder up 2 Place the SIM card as presented in the picture Close the holder by lowering it down and gently pushing the metal clamp Make sure that the bevelled corner points outwards from the PCB 3 S Close the holder by lowering it down and gently pushing the metal clamp until it locks into position ...

Страница 9: ...own mobile phone and remove the PIN code query Remove all phone numbers from the SIM card and also remove all SMS messages Insert the SIM card into the me me me metis tis tis tis USB USB USB USB Connect a power supply Wait until the green GSM light is lit this typically takes 30s to 1min Press the programming button until the green light starts to blink approx 10 seconds Call me me me metis tis ti...

Страница 10: ... 24V batteries have a typical char char char charging voltage of 27 ging voltage of 27 ging voltage of 27 ging voltage of 27 28VDC 28VDC 28VDC 28VDC 4 4 4 4 2 2 2 2 Start Start Start Start up up up up Connect the power supply me me me metis tis tis tis Micro Micro Micro Micro automatically connects to the GSM network This takes approximately a minute during which the red wait fault led is constant...

Страница 11: ... loads please use external relays It is also recommended to use a diode over the coil of the external relay to prevent harmful transients Note Under any circumstances do not connect 230VAC volta Note Under any circumstances do not connect 230VAC volta Note Under any circumstances do not connect 230VAC volta Note Under any circumstances do not connect 230VAC voltage to the device ge to the device g...

Страница 12: ...o Micro Micro sends an alarm message according to the input s number The alarm text can be set freely see 6 2 Alarm messages The direction of operation N O N C of each input can be set individually see 6 4 Input settings It is also possible to specify whether it is reported when the input s return to normal state after an alarm see 6 9 General settings 5 3 5 3 5 3 5 3 Entry exit delay and response...

Страница 13: ...sensitive and can be activated as described in 6 4 Input Settings The calling sound from the device is 4 times short peep sound 5 5 5 5 5 5 5 5 Lock Lock Lock Lock up up up up If me me me metis tis tis tis Micro Micro Micro Micro detects over 20 alarm events in one hour the device locks up to prevent unnecessary message sending When the device is locked up the red light wait fault is on Also if mo...

Страница 14: ... back a message ERROR These acknowledgement messages are sent only to authorized numbers numbers that are stored in the phonebook 6 6 6 6 1 1 1 1 Lan Lan Lan Language setting guage setting guage setting guage setting me me me metis tis tis tis Micro Micro Micro Micro has a few non configurable standard messages that can can be sent in different languages The standard messages include for example t...

Страница 15: ...ng phone numbers with SMS umbers with SMS umbers with SMS umbers with SMS Message format 91 358xxxxxxxx 91 358xxxxxxxx 91 358xxxxxxxx 91 358xxxxxxxx user 1 master user 92 358xxxxxxxx 92 358xxxxxxxx 92 358xxxxxxxx 92 358xxxxxxxx user 2 93 358xxxxxxxx 93 358xxxxxxxx 93 358xxxxxxxx 93 358xxxxxxxx user 3 915 358xxxxxxxx 915 358xxxxxxxx 915 358xxxxxxxx 915 358xxxxxxxx user 15 358xxxxxxxx 358xxxxxxxx 35...

Страница 16: ... 05 1 1 02 05 1 1 02 05 1 1 02 05 1 1 Input 2 is set with a 5 second response time the alarm is registered after the input has been 5 seconds consecutively in alarming state the backup call feature is activated and the direction of operation is set to N O normally open 6 6 6 6 5 5 5 5 Inputs that follow arm disarm event Inputs that follow arm disarm event Inputs that follow arm disarm event Inputs...

Страница 17: ...gs 6 7 Restoring factory settings 6 7 Restoring factory settings The factory defaults of me me me metis tis tis tis Micro Micro Micro Micro can be restored with a jumper block see 9 Connectors When the device is started with the jumper block in place the factory settings are restored 6 6 6 6 8 8 8 8 Alarm output Alarm output Alarm output Alarm output Alarm siren output is active for 20 seconds dur...

Страница 18: ...10 10 10 Factory settings Factory settings Factory settings Factory settings Language setting Language setting Language setting Language setting 00 0 Finnish Input settings Input settings Input settings Input settings 01 00 0 0 input 1 no entry exit delay only SMS N C 02 00 0 0 input 2 immediate response only SMS N C General settings General settings General settings General settings 06 00100 Armi...

Страница 19: ... 7 7 7 CONTROL COMMANDS AND CONTROL COMMANDS AND CONTROL COMMANDS AND CONTROL COMMANDS AND QUERIES QUERIES QUERIES QUERIES 7 7 7 7 1 1 1 1 Relay commands Relay commands Relay commands Relay commands Relay on 11 11 11 11 Relay off 10 10 10 10 Relay on 5s pulse 31 31 31 31 Relay on adjustable pulse 31 a 31 a 31 a 31 a a time in minutes 1 999 Example 31 60 31 60 31 60 31 60 Relay is activated for 60 ...

Страница 20: ...Metis micro user manual v1 6 20 8 8 8 8 CONNECTORS CONNECTORS CONNECTORS CONNECTORS ...

Страница 21: ...Metis micro user manual v1 6 21 9 9 9 9 CONNECTION EXAMPLES CONNECTION EXAMPLES CONNECTION EXAMPLES CONNECTION EXAMPLES ...

Страница 22: ...l Construction File me me me metis tis tis tis Micro Micro Micro Micro We the manufacturer of the above mentioned products hereby declare that these products conform to the essential requirements of the European Union directive 2004 108 EC This Declaration of Conformity is based on using the Harmonized European Standards and relevant Articles of the RTTE directive Article 3 1a Protection of the he...

Страница 23: ...Metis micro user manual v1 6 23 ...

Страница 24: ...Metis micro user manual v1 6 24 ...

Отзывы: