switch “ON” in the back of the T-1400. If you are using the DMX features, read the section on DMX
settings to get the proper response. If you are using the remote, set the DMX display on the back of
the T-1400 unit to any number between 900-999. Press the “ON” switch on the tethered remote to
start the snowfall. Adjust the dial on the remote to set the desired snowflake size (See Chart 2).
Rotate the dial clockwise to obtain larger flakes and counterclockwise for smaller flakes. If the flakes
are sticking to the ground during an initial run, adjust the dial counterclockwise, after drying off the
ground surface (snowflakes accumulate more easily on a wet surface). Press “OFF” to turn off the
snow on the tethered remote. Do not operate the T-1400 without the clear tube submerged in the
filled solution container.
5)
If the solution has drained out of the clear tube during a rest period for
the T-1400, it may take a minute or two for the pump to self-prime itself
from the solution container liquid.
6)
On the tethered remote, a blinking light signifies that the power is
“ON”. A constant light from the LED signifies that the T-1400 is blowing
Evaporative Snow. If the light on the remote is completely off, the unit is
not powered up and cannot be controlled from the remote.
7)
To turn the power OFF, push down on the red “O” button on the back of
the unit.
DMX Settings T-1400 “The Quiet Snow Machine”
The DMX settings are key to the operation of the T-1400. The three-digit number on the back of the
T-1400 panel determines the operation mode for the T-1400. Warning: there are DMX settings where
the T-1400 will appear not to operate, so always review the tables below during setup and operation .
8
9
6
RANGE
ACTIVITY
001
500
DMX Address- Outside Interface
501
599
Standby- No Activity
600
699
Short Cycles of ON/OFF Activity
700
799
Long Cycles of ON/OFF Activity
800
849
Zero to Minimal Snow-Blower Operates
850
859
Snow Flurry- Lowest Outputs
860
879
Light Snowfall- Smallest Flakes
880
889
Sub-Blizzard- Larger Snow Flakes
890
895
Ideal Range of Operation at 30 ft height
896
899
Maximum Snow Output- Largest Flakes
900
999
Remote Control Activated (Note: 5 Pin DMX
must be disconneted.)
See Chart 2 for Remote Controlled Flake Size
O
p
e
ra
tin
g
In
st
ru
ct
io
n
s
Operating Instructions:
General Operating Instructions
*** THE DMX TERMINATOR MUST BE PLUGGED IN
FOR DMX FUNCTIONALITY TO WORK PROPERLY ***