Global Leak Detection GLD-40 Скачать руководство пользователя страница 16

MATERIAL SAFETY DATA SHEET

Page 2 of 4

PRODUCT NAME:

UltraTraceUV®

(Fluorescent Diagnostic Smoke® Solution)

PRODUCT PART NUMBERS:

GLD0712UV | GLD0708UV

DATE: June 25, 2011

EYES:

SKIN:

TWA ppm

TWA mg/m3

STEL ppm

STEL mg/m3

TLV/TWA ppm

TWA mg/m3

STEL ppm

STEL mg/m3

NE

NE

NE

NE

NE

NE

NE

NE

Water Spray (Fog), Foam, Dry Chemical and Carbon Dioxide.

INHALATION:

INGESTION:

Flush eyes with clean water for 15 minutes or until irritation subsides. If irritation persists, consult a physician.

NIOSH

Do not handle or store near heat, flames or strong oxidants.

PERSONAL PROTECTION

SECTION 8 - EXPOSURE CONTROLS / PERSONAL PROTECTION

Inhalation at ambient temperatures is not commonly a problem. If overcome by excessive exposure to vapors,
you should remove from exposure to well ventilated area. Some people may experience dizziness, drowsiness or nausea.
If symptoms persist, consult a physician. It is always a good measure of precaution to avoid excessive inhalation of byproduct.

RESPIRATORY PROTECTION:

EYE PROTECTION:

PROTECTIVE GLOVES:

Combustible liquid Flash Point: 335-510°F (168-265°C). Distillation Range: 550-900° F (288-482° C). LEL:0.9% UEL: 7.0%

EXTINGUISHING MEDIA:

PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE:

OTHER PROTECTIVE CLOTHING OR EQUIPMENT:

HAZARDOUS COMBUSTION PRODUCTS:

Carbon Monoxide, Soot, Smoke, Carbon Dioxide.

Non-Hazardous

SECTION 4 - FIRST AID MEASURES

SECTION 5 - FIRE FIGHTING MEASURES

Do not induce vomiting

as a risk of aspiration exists with this petroleum based product. If ingested, the precaution is to call a physician and our

emergency number immediately.

Remove any contaminated clothing and wash affected skin area with soap and warm water.

SECTION 7 - HANDLING AND STORAGE

SECTION 6 - ACCIDENTAL RELEASE MEASURES

UNUSUAL FIRE AND EXPLOSION HAZARDS:

ACGIH

OSHA

HAZARDOUS COMPONENTS

GENERAL HAZARDS:

FIRE FIGHTING PROCEDURES:

STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED:

Do not store or mix base chemical with strong oxidants. Do not cut, drill, grind, or weld container, as this may cause explosion.

Cool exposed container with water. Use air-supplied (SCBA) breathing equipment for enclosed or confined spaces.

Recover liquid, wash remainder with suitable petroleum solvent or add absorbent. As with all petroleum products, keep out of sewers and water
courses. Advise authorities if ever any petroleum product has entered or may enter sewers or water courses

Use this product in a well ventilated area.

Wash with soap and water after using this product and before eating drinking or smoking.

Eyewash station recommended.

Safety Glasses required.

Not required.

WORK / HYGIENIC PRACTICES:

Содержание GLD-40

Страница 1: ...OPERATOR S MANUAL Diagnostic Smoke Vapor Machine with UltraTraceUV Dye Solution Leak Detection System Model No GLD 40 USA Canada Patents 6 392 227 6 526 808 2 279 147 Int l Patents Pending...

Страница 2: ......

Страница 3: ...be between 50 175 PSI 3 4 to 12 bar Connect to workshop airline for general purpose leak detection applications Smoke exiting a very small leak is sometimes even easier to see if after filling the sy...

Страница 4: ...e leak detection smoke machine available today The patented technology inside your Smoke Wizard was designed in collaboration with major automakers was designed specifically to be safe for leak testin...

Страница 5: ...remove Cap Plugs Kit GLD005 these cap plugs are useful when sealing an intake manifold system in order to contain the smoke in the system for proper leak testing such as mass airflow sensor ducting e...

Страница 6: ...end it The patented UltraTraceUV smoke solution supplied with this Tester will perform hundreds of tests that only cost pennies per test is the only solution in the world approved by the auto manufact...

Страница 7: ...Smoke Wizard from a convenient test location on the vehicle or for storage when not in use Note Always use bonnet support device when hanging from the bonnet Filter Drain Port located under Tester ke...

Страница 8: ...the leak is even easier to see Sometimes less smoke exiting a small leak is easier to see Flow Control Valve does not affect delivery pressure it only affects the volume of flow SMOKE Light Red Turns...

Страница 9: ...ter 5 Connect smoke supply hose to system being tested 6 Flow Control Valve must be in Full Open position Figure 3 7 Press START button and fill system with smoke Whenever possible it is best to purge...

Страница 10: ...aving a leak such as intake induction system intercooler and turbocharger system vacuum system exhaust system wind water leaks and can also be used to verify air solenoid functions and test components...

Страница 11: ...iv ve e c ca ab bi in n p pr re es ss su ur re e 2 2 C Co on nn ne ec ct t T Te es st te er r s s s su up pp pl ly y h ho os se e n no oz zz zl le e t to o S Sm mo ok ke e D Di if ff fu us se er r 3 3...

Страница 12: ...location of a leak Use the UV light provided to highlight the dye This technology is designed so that the dye will only deposit if there is pressure differential So for instance the dye will deposit w...

Страница 13: ...itive terminal and chassis ground 3 Verify the battery is in good condition and fully charged I turn the Tester ON but there is no air or smoke coming out of the supply hose 1 Flow Control valve is cl...

Страница 14: ...ormal use care and service the Equipment except as otherwise provided herein shall be free from defects in material and workmanship for ONE YEAR from the date of original invoice Seller s obligations...

Страница 15: ...ry injury may occur EMERGENCY OVERVIEW INHALATION INGESTION The balance of the ingredients are proprietrary and non hazardous as defined in US 29CFR 1210 and European regulation directive 67 548 EEC S...

Страница 16: ...R PROTECTIVE CLOTHING OR EQUIPMENT HAZARDOUS COMBUSTION PRODUCTS Carbon Monoxide Soot Smoke Carbon Dioxide Non Hazardous SECTION 4 FIRST AID MEASURES SECTION 5 FIRE FIGHTING MEASURES Do not induce vom...

Страница 17: ...NA NA NA UN NA IDENTIFICATION NUMBER NA SECTION 14 TRANSPORT INFORMATION Not regulated Not regulated IATA HAZARD CLASS Pack Group SECTION 12 ECOLOGICAL INFORMATION No ecological information is availa...

Страница 18: ...so ChemTel Inc assumes no responsibility for document alterations or additions after authorship and initial review excepting changes performed by ChemTel personnel Data and calculations are based on...

Страница 19: ...is report by itself does not imply that the material product or service is or has ever been under an Intertek certification program Intertek Testing Services NA Inc EMC VERIFICATION No 3179331LAX 001g...

Страница 20: ......

Страница 21: ...ry injury may occur EMERGENCY OVERVIEW INHALATION INGESTION The balance of the ingredients are proprietrary and non hazardous as defined in US 29CFR 1210 and European regulation directive 67 548 EEC S...

Страница 22: ...R PROTECTIVE CLOTHING OR EQUIPMENT HAZARDOUS COMBUSTION PRODUCTS Carbon Monoxide Soot Smoke Carbon Dioxide Non Hazardous SECTION 4 FIRST AID MEASURES SECTION 5 FIRE FIGHTING MEASURES Do not induce vom...

Страница 23: ...NA NA NA UN NA IDENTIFICATION NUMBER NA SECTION 14 TRANSPORT INFORMATION Not regulated Not regulated IATA HAZARD CLASS Pack Group SECTION 12 ECOLOGICAL INFORMATION No ecological information is availa...

Страница 24: ...so ChemTel Inc assumes no responsibility for document alterations or additions after authorship and initial review excepting changes performed by ChemTel personnel Data and calculations are based on...

Страница 25: ...is report by itself does not imply that the material product or service is or has ever been under an Intertek certification program Intertek Testing Services NA Inc EMC VERIFICATION No 3179331LAX 001g...

Отзывы: