Wall Mounted Filtered

Water Cooler

8

User's Manual

Operation

Note:

 Initial water flow may have sputter due to air in the 

water lines; this will be eliminated once air is purged from 

all water lines.
To operate drinking fountain, push front or side activation 

buttons on the stainless steel pan to dispense cooled-

filtered water from the bubbler.

Adjusting Settings

Water Flow Pressure:  Adjust the water flow pressure as 

needed by turning the water control valve.  Turn clockwise 

to decrease the water pressure, or counterclockwise to 

increase the water pressure.

Note:

 When adjusting, aim water flow to the center of the 

stainless steel pan.

Note:

 Initial dispenses may have air in line which may 

cause a sputter. Allow a few seconds for air to be purged 

from the water line.
Water Temperature: Machine comes with a preset water 

temperature of around 45°F. If a different temperature is 

required, remove Lower Cover and access the thermostat 

on the front housing frame. Using a flathead screwdriver, turn 

thermostat screw clockwise to lower temperature setting.  

Note:

 Please allow 5-10 minutes for water temperature 

to change.

Installing/Replacing Filter

1.  Remove filter access door on the lower cover using the 

provided key (H4).

2. Grasp old filter and turn counterclockwise to remove 

from the filter head.

3.  Insert new filter onto filter head by turning the filter 

clockwise until locked into place.

4. Reinstall and lock the filter access door.
Replacement Filters: Model 670336

For more information visit: globalindustrial.com or 

call 1-800-645-2982.

Water 

Filter

H4

Filter Status Lights

When filter level is at 100%

5 LED bars will be displayed

When filter level is at 80% 

4 LED bars will be displayed

When filter level is at 60% 

3 LED bars will be displayed

When filter level is at 40% 

2 LED bars will be displayed

When filter level is at 20% 

1 LED bar will be displayed

When filter level is at 10% 

1 LED bar will be displayed and will FLASH

When filter level is at 0% 

5 LED bars will be displayed and will FLASH

Содержание 761217

Страница 1: ...in this manual All other services should be referred to a qualified technician For use with clean clear potable drinking water only Shut off water supply during installation to reduce risk of water d...

Страница 2: ...7 Pencil 8 Level Device 9 8 75 lb Capacity Flat Head Wall Anchors appropriate for your wall type 10 8 Flat Head Anchor Screws WARNING Review manual thoroughly and verify rough ins before installation...

Страница 3: ...3 User s Manual Wall Mounted Filtered Water Cooler Check local codes for plumbing requirements prior to installation...

Страница 4: ...Filler Access Door Key WARNING Assembly and installation of equipment should be performed by 2 people 1 2 H2 H1 1 2 3 Remove Lower Cover Using the Anti Theft Screw Star Key remove the 4 screws at the...

Страница 5: ...blue Activation Connectors B to the Solenoid Valve B Attach stainless steel pan Feed the Reset Button Connection through the Cooling System s frame and carefully lower the Stainless Steel Pan on top o...

Страница 6: ...e wall using appropriate anchors 4 5 CAUTION Hanging assembled unit to wall Carefully hang assembled unit onto the wall by lowering onto mounting bracket WARNING installation of equipment should be pe...

Страница 7: ...on button Connect the Reset Button connection cable to the Activation Buttons located at the top of the filter access door frame Reinstall the filter access door using the provided key Unit is now rea...

Страница 8: ...Lower Cover and access the thermostat onthefronthousingframe Usingaflatheadscrewdriver turn thermostat screw clockwise to lower temperature setting Note Please allow 5 10 minutes for water temperature...

Страница 9: ...s will be displayed Tap SET button 3 times to select 1500 gallon filter option 2 LED lights will be displayed Tap SET button 4 times to select NO filter option 1 LED lights will be displayed 3 Tap ENT...

Страница 10: ...water drain Note Wiping the surface clean to remove debris or build up will not hurt the antimicrobial properties Maintenance Issue Possible Cause Suggested Action Water Temperature not Cool The ther...

Отзывы: