Note:
Initial water flow may have sputter due to air in the
water lines; this will be eliminated once air is purged from
all water lines.
To operate drinking fountain, push front or side activation
buttons on the stainless steel pan to dispense cooled-
filtered water from the bubbler.
Adjusting Settings
Water Flow Pressure: Adjust the water flow pressure as
needed by turning the water control valve. Turn clockwise
to decrease the water pressure, or counterclockwise to
increase the water pressure.
Note:
When adjusting, aim water flow to the center of the
stainless steel pan.
Note:
Initial dispenses may have air in line which may
cause a sputter. Allow a few seconds for air to be purged
from the water line.
Water Temperature: Machine comes with a preset water
temperature of around 45°F. If a different temperature is
required, remove Lower Cover and access the thermostat
on the front housing frame. Using a flathead screwdriver, turn
thermostat screw clockwise to lower temperature setting.
Note:
Please allow 5-10 minutes for water temperature
to change.
Installing/Replacing Filter
1. Remove filter access door on the lower cover using the
provided key (H4).
2. Grasp old filter and turn counterclockwise to remove
from the filter head.
3. Insert new filter onto filter head by turning the filter
clockwise until locked into place.
4. Reinstall and lock the filter access door.
Replacement Filters: Model 670336
For more information visit: globalindustrial.com or
call 1-800-645-2982.
Water
Filter
H4
Filter Status Lights
When filter level is at 100%
5 LED bars will be displayed
When filter level is at 80%
4 LED bars will be displayed
When filter level is at 60%
3 LED bars will be displayed
When filter level is at 40%
2 LED bars will be displayed
When filter level is at 20%
1 LED bar will be displayed
When filter level is at 10%
1 LED bar will be displayed and will FLASH
When filter level is at 0%
5 LED bars will be displayed and will FLASH