CAUTION
Make sure all wires are
tucked in before attaching
cover plate to lower cover.
7
Assembly Instructions
Wall Mounted Filtered
Water Cooler
Install water filter
• Remove the receiver protective cover
from the water filter.
• Insert filter into the filter head by turning
clockwise until locked into place.
•
Turn water control valve #1 to the
open position.
•
Keep water control valve #2 in the
closed position
• Check all connections for leaks. If leaks
are detected ensure all connections are
tight and are fully inserted.
7
8
11
10
9
6
Water Filter
Counter Clockwise to remove
Clockwise to install
Filter access door key
Open water control
valve #1
(CHECK FOR LEAKS)
Keep Closed #2
• Turn on buildings water supply and
check all connections for leaks.
• Fix any leaks before continuing.
• Plug power cord into outlet.
• Remove the filter access door using
the provided key.
Reattach lower cover
•
Reattach the Lower Cover to the Cooling
System using (6) H1 anti-theft screws.
Connect reset cable to activation button
• Connect the Reset Button connection cable to the Activation
Buttons located at the top of the filter access door frame.
• Reinstall the filter access door using the provided key.
• Unit is now ready for use.
WARNING
Risk Of Electrical Shock
• Turn off power prior to performing any maintenance.
• Verify supply voltage accuracy.
• Ensure all electrical and grounded connections are in accordance with the National
Electrical Code and any other applicable local code requirements.
• All wiring connections should be capped with approved wire connectors.
The warnings, precautions, and instructions discussed cannot cover all possible
conditions and situations that may occur. Failure to heed these warnings may result in
property damage and personal injury.
General Safety Information
• To reduce the risk of property damage, personal injury, electric shock, falling
equipment, and other hazards please read all instructions and warnings.
• Installation, service, and maintenance should be
• All parties must follow proper safety procedures and precautions at all times.
• Do Not Install Damaged Products!
2
H1
H1
H4
5
Reset button connection
Check local codes for plumbing requirements
prior to installation.