FIELD CONVERSION FOR LOWER
FIELD CONVERSION FOR LOWER
WATTAGE RATINGS
WATTAGE RATINGS
NOTE: Refer to "Specifications" for available lower wattage ratings
To convert heater to lower wattage rating, completely remove red jumper wire from
both heating elements (see Figure 2). Do not remove or damage other wires or pins in
the process. Discard the removed jumper wire.
INSTALLATION AND WIRING OF
INSTALLATION AND WIRING OF
HEATER/FAN ASSEMBLY
HEATER/FAN ASSEMBLY
1. Use the following wiring diagram (Figure 3) to connect supply wiring to heater
lead wires in back box.
2. Connect the white neutral supply lead to the heaters white pigtail lead, and
connect the black supply lead to the heater black pigtail lead.
3. Two (2) metal retaining straps are provided in back box to secure wires. Carefully
fold supply and heater wires along side of box and secure by bending the retaining
straps up and over the wires.
4. Insert wiring plug from heater/fan assembly into socket in back box.
CAUTION: The supply and heater wires in the back box could be damaged if they
are allowed to contact the heating element of fan blade. Be sure are secured by
bending the straps up and over the wires to hold them in place.
5. Fit heater/fan assembly into back box and secure in place with (2) screws provided
through the center slots in the fan assembly.
NOTE: Use the screws provided by the factory to install fan deck to the back box.
Fan Forced Wall Heater
5