background image

3

Fan Forced Wall Heater

SAFETY INSTRUCTIONS

SAFETY INSTRUCTIONS

WARNING

1.  Before wiring or servicing, disconnect all power coming to heater at main service 

panel.

2.  All wiring procedures and connections must be in accordance with National and 

Local Codes having jurisdiction.

3.  Heater must be properly grounded.

4.  Power supply must enter back box through the knockouts 

5.  Heater nameplate states voltage rating for unit. IF THE HEATER POWER SUPPLY IS 

GREATER THAN THE RATED VOLTAGE, PERMANENT DAMAGE TO THE HEATER MAY 
OCCUR AND WARRENTY WILL BE VOIDED. HIGH VOLTAGE ALSO PRESENTS RISK OF 
FIRE, DO NOT EXCEED VOLTAGE ON NAMEPLATE.

6.  CAUTION: Keep combustibles such as electrical cords, draperies, furnishings, and 

paper goods at least 3 ft (0.9 m) from front of heater. DO NOT install heater behind 
doors, below towel racks, or in areas where it may be blocked by furniture, curtains 
or storage materials. Hot air from heater also may damage furniture and plastic 
goods. DO NOT store or use gasoline or other flammable vapors or liquids in the 
vicinity of the heater.

7.  Do not operate the heater without the grille installed.

8.  This heater must be mounted to a wall using the back box. Unit may be installed 

with the back box recessed or surface mounted as described within this manual.

9.  The following minimum clearances must be adhered to:

Heater bottom to floor: 4” (102 mm), optimum height 18” – 24” (457 – 610 mm)

Heater sides to adjacent wall: 4 ½” (114 mm), optimum distance 12” (305 mm)

Heater top to ceiling: 12” (305 mm), optimum distance 36” (915 mm)

10. Do not use the heater for drying purposes. Paint, plaster, sawdust, drywall sanding 

and other materials may cause permanent damage to the heater and must be kept 
out of the ventilation system.

Содержание 246744

Страница 1: ...Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury and or property damage Retain instructions for future reference NOTE...

Страница 2: ...er outdoors 7 To disconnect heater set on off switch to off and disconnect power to heater circuit at main service panel 8 Do not allow any foreign object to enter or block any air intake ventilation...

Страница 3: ...eater DO NOT install heater behind doors below towel racks or in areas where it may be blocked by furniture curtains or storage materials Hot air from heater also may damage furniture and plastic good...

Страница 4: ...he connector into the box Leave about 8 of wire inside the box 5 Connect the supply cable ground wire to green ground screw provided NOTE Lead holes for a 8 sheet metal screw have been provided in the...

Страница 5: ...ers white pigtail lead and connect the black supply lead to the heater black pigtail lead 3 Two 2 metal retaining straps are provided in back box to secure wires Carefully fold supply and heater wires...

Страница 6: ...ow heater to continue operating until desired room temperature is reached then turn thermostat knob counterclockwise until thermostat clicks off The fan will continue operating until the element cools...

Страница 7: ...e one shot that will permanently shut the heater off if for some reason the over temperature safely control should not function as intended If this thermal fuse activates the heater will cannot be res...

Отзывы: