THE ORION EX MINI-REP SYSTEM STATUS INDICATORS
AND CONTROL BUTTONS

STATUS

FIRE

LED used to indicate any FIRE ALARM condition present on panel.

FAULT

LED used to indicate any FAULT condition present on panel.

DISABLED 

Disabled Status LED used to indicate that the panel has features that have been disabled in 
either Access Level 2 or 3 modes.

TEST

This LED is active whenever panel is in TEST MODE. Only LIT when in Engineering Mode and 
TEST mode has been selected.

SUPPLY

Multi function indicator used to indicate the presence of supply. When in Access Level 1 this 
LED is permanently lit. If in Access Level 2 (enter this mode using USER CODE) this LED will flash 
at a rate of once per second. And finally if in Access Level 3 mode (enter using ENGINEERING 
CODE) this LED will flash faster at a rate of once every 0,5 seconds.

SYSTEM FAULT This LED will be lit whenever there is a processor failure or corruption of the panel firmware.

Manufacturers of Fire Detection Equipment

globalfire.pt

INSTALLATION MANUAL 1.0 - 06/2015

ORION EX MINI-REP

Содержание ORION EX MINI-REP

Страница 1: ...ufacturers of Fire Detection Equipment globalfire pt INSTALLATION MANUAL 1 0 06 2015 ORION EX MINI REP INSTALLATION MANUAL VERSION 1 0 06 2015 ORION EX MINI REP EXTINGUISHING CONVENTIONAL REPEATER PAN...

Страница 2: ...Panel using 4 different interconnecting technologies RS 232 RS 485 Fiber Optics and TCP IP The unit is provided as standard with an RS 232 interface Power for the ORION EX MINI REP can be supplied fro...

Страница 3: ...ere are no open or shortcircuitsonanyoftheinterconnectingwiresusedforbothsupplyanddatatransmission Allconnectionsshouldbeperformedwithallelementsofthefiredetectionsystemunpowered The Repeater should b...

Страница 4: ...CAL DETAILS 256 mm 246 mm 75 mm 194 mm 187 mm Rear Cable Entry Orion Ex Mini Rep Data Loop Interface PCB Stand offs Orion Ex Mini Rep Back Box Mounting Holes Manufacturers of Fire Detection Equipment...

Страница 5: ...al Hardware and Connections Layout Connect Orion Ex Mini Rep CON3 Data Loop to corresponding interface 24 V DC Ground 0V Earth Manufacturers of Fire Detection Equipment globalfire pt INSTALLATION MANU...

Страница 6: ...lpanel AllotherOrion ExMini Rep s willonlybeabletodisplaysystemstatus Maximum distance between Panel and last Orion Ex Mini Rep shouldbe100meters Connect to cable screens ORION EX MINI REP Interface 2...

Страница 7: ...2 b NOTES On Orion Panel interface JP1 and JP2 should be removed On Orion Ex Mini RepinterfaceJP1andJP2shouldbeON Interface CON3 should be connected to DATA connector Cn3 placed on the undersideofthe...

Страница 8: ...when in Engineering Mode and TESTmodehasbeenselected SUPPLY Multi function indicator used to indicate the presence of supply When in Access Level 1 this LEDispermanentlylit IfinAccessLevel2 enterthis...

Страница 9: ...onlybeoperational attherepeaterafterenteringtheauthorisedusercode Iftheoperation of a switch is only available after succesfully entering the authorised user code it will be clearly stated in this man...

Страница 10: ...r the duration of the previously programmed extinguihing time Sounder Circuit 1 will also be activated When the extinguishing cycle is initiated manually the pre extinguishing delay is not obeyed Thee...

Страница 11: ...ATION MANUAL 1 0 06 2015 ORION EX MINI REP GLOBAL FIRE EQUIPMENT S A S tio dos Barrab s Armaz m Nave Y Caixa Postal 908 Z 8150 016 S o Br s de Alportel PORTUGAL Tel 351 289 896 560 Sales sales globalf...

Отзывы: