Please read this instruction manual carefully
before using the instrument. This manual will
provide you with all the necessary information
for the correct use of the instrument.

This meter is in compliance with European
Community (CE) directives EN 50081-1 and
EN 50082-1.

TABLE OF CONTENTS

PRELIMINARY EXAMINATION ................................. 2

GENERAL DESCRIPTION ........................................ 2

SPECIFICATIONS.................................................. 2-3

OPTIONAL REAGENT ACCESSORIES .................... 3

DISPLAY CODE........................................................ 3

OPERATIONAL GUIDE.......................................... 4-5

TIPS FOR AN ACCURATE MEASUREMENT............ 5

BATTERY REPLACEMENT ...................................... 5

WARRANTY.............................................................. 5

PRELIMINARY EXAMINATION

Remove the instrument from the packing
material and examine it carefully to make
sure that no damage has occurred during
shipping. If there is any damage, notify the
transit carrier immediately.

Each meter is supplied complete with:

 Two sample cuvets and caps

 One transport cap

 Instruction Manual

 One 9 Volt Battery

NOTE:

Save all packing material until you
are sure that the instrument func-
tions correctly. All defective items
must be returned in their original
packaging together with the supplied
accessories.

GENERAL DESCRIPTION

The meter measures the free and total chlo-
rine (Cl

2

) content in water and wastewater.

The meter uses an exclusive positive-locking
system to ensure that the cuvet is in the
same place every time it is placed into the
measurement cell.

The reagents are in liquid form and are sup-
plied in bottles. The amount of reagent is
precisely dosed to ensure maximum repeat-
ability.

Display codes aid the user in routine opera-
tions.

The meter has an auto-shut off feature that
will turn the instrument off after 10 minutes of
non-use.

SPECIFICATIONS

METER

Содержание GLI-93711

Страница 1: ...Manual No 93711 Revision 0 401 MODEL GLI 93711 HAND HELD PORTABLE TOTAL FREE CHLORINE METER ...

Страница 2: ...age notify the transit carrier immediately Each meter is supplied complete with Two sample cuvets and caps One transport cap Instruction Manual One 9 Volt Battery NOTE Save all packing material until you are sure that the instrument func tions correctly All defective items must be returned in their original packaging together with the supplied accessories GENERAL DESCRIPTION The meter measures the...

Страница 3: ...he meter is in a ready state and ze roing can be performed Sampling in Progress This prompt appears each time the meter is performing a measurement This indicates that the meter is in a zeroed state and measurement can be per formed A zero reading was not taken Insert a sample be fore adding reagent and press ZERO Under range A blinking 0 00 indicates that the sample absorbs less light than the ze...

Страница 4: ...Free Chlorine add 3 drops of DPD1 indicator Bottle A and 3 drops of DPD1 buffer Bottle B to the other cuvet To measure Total Chlorine also add 1 drop of DPD3 solution Bottle C Shake gently before adding 10 ml of unreacted sample from the first cuvet Replace the cap and shake gently again 10 Reinsert the cuvet into the instrument 11 Wait for approximately 30 seconds and then press READ The display ...

Страница 5: ... 68 F As a general rule they should be doubled at 10 C 50 F and halved at 30 C 86 F BATTERY REPLACEMENT When the battery is low BA is displayed to indicate that it must be replaced Battery replacement must only take place in a non hazardous area To replace a run down battery simply remove the battery compart ment cover on the rear of the meter and replace the battery observing correct polarity WAR...

Отзывы: