Glensound AOIP22 Скачать руководство пользователя страница 3

Page 

3

 of 

29

 

 

IMPORTANT SAFETY INSTRUCTIONS

 

 

1) 

Read these instructions

 

2) 

Keep these instructions

 

3) 

Heed all warnings

 

4) 

Follow all instructions

 

5) 

Do not use this apparatus near water

 

6) 

Clean only with a dry cloth

 

7) 

Do not block any ventilation openings. Install in accordance with manufacturer’s 
instructions

 

8) 

Do not install near any heat sources such as radiators, heat registers, stoves, or other 
apparatus (including amplifiers) that produce heat

 

9) 

Do not defeat the safety purpose of the polarized or grounding type plug. A polarized 
plug has 2 blades with one wider than the other. A grounding type plug has 2 blades and 
third grounding prong. The wider blade or the 3

rd

 prong are provided for your safety. If 

the provided plug does not fit into your outlet, consult an electrician for replacement of 
the obsolete outlet

 

10) 

Protect the power cord from being walked on or pinched, particularly at plugs, 
convenience receptacles and the point where they exit from the apparatus

 

11) 

Only use attachments/ accessories specified/ supplied by the manufacturer

 

12) 

Use only with the cart, stand, tripod, bracket, or table specified by the 

manufacturer, or sold with the apparatus. When a cart is used, use caution when moving 
the cart/ apparatus combination to avoid injury from tip over

 

13) 

Unplug tis apparatus during lightning storms or when unused for long periods of time

 

14) 

Refer all servicing to qualified service personnel. Servicing is required when the 
apparatus has been damaged in any way, such as power supply cord or plug is damaged, 
liquid has been spilled or objects have fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, or has been dropped

 

15) 

Do not attempt to modify this product. Doing so could result in personal injury and/ or 
product failure   

  

 

                               

 

This symbol is intended to warn that 
dangerous voltages within the product are 
present and constitute a risk of electric shock.

 

                               

 

This symbol is intended to highlight that there 
are important operating & maintenance 
instructions in the literature accompanying 
this unit.

 

Содержание AOIP22

Страница 1: ...AES67 NETWORK AUDIO 2 INPUT 2 OUTPUT LINE LEVEL ANALOGUE INTERFACE PRODUCT DETAILS 6 BROOKS PLACE MAIDSTONE KENT ME14 1HE ENGLAND TEL 44 0 1622 753662 Visit our Website at www glensound com FAX 44 0...

Страница 2: ...bt please contact us for the latest product information If you need any help with the product then we can be contacted at Glensound Electronics Ltd 1 6 Brooks Place Maidstone Kent ME14 1HE United King...

Страница 3: ...point where they exit from the apparatus 11 Only use attachments accessories specified supplied by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufactur...

Страница 4: ...goods against any defect developing after proper use providing such defects arise solely from faulty materials or workmanship and that the Customer shall return the goods to the Company s works or th...

Страница 5: ...quipment is manufactured by Glensound Electronics Ltd of Brooks Place Maidstone Kent ME14 1HE is CE marked and conforms to the following Union harmonisation legislation Low Voltage Directive EN60065 a...

Страница 6: ...rical and electronic equipment This product conforms to the above directive and for this purposes the maximum concentration values of the restricted substances by weight in homogenous materials are Le...

Страница 7: ...e 7 of 29 WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT REGULATIONS 2006 WEEE Glensound Electronics Ltd is registered for business to business sales of WEEE in the UK our registration number is WEE JJ0074...

Страница 8: ...LAYOUT 13 AOIP22 LEFT SIDE PANEL LAYOUT 14 SIMPLIFIED BLOCK DIAGRAM 15 CONNECTING THE AoIP22 TO A DANTE NETWORK 16 Getting Dante Controller 16 Connecting AoIP22 To the Network 16 Audio Over IP Networ...

Страница 9: ...plications the AOIP22 is built into a rugged lightweight aluminium chassis with anaodised and laser etched panels Holes suitable for temporarily attaching the unit with cable ties to hold it in place...

Страница 10: ...booth and connected intothebroadcastnetwork viaasingleCAT5 6 cable The Glensound GS CU008A is a popular and widely used commentary unit by broadcasters It provides a programme output and has a talkba...

Страница 11: ...hannel ISDN or Ip Codec The AoIP22 is installed in the back of the rack using cable tiesthrough thefasteningpoints It is then connected to the network switch in the station s racks room this switch pr...

Страница 12: ...el whereby full scale 0dBFs on the digital network equates to an analogue output of 18dBu 2 Analogue Audio Inputs The two balanced analogue XLR inputs provide inputs to the Dante AES67 network They ar...

Страница 13: ...tly communicated with the attached switch 4 Network Connection The Ethercon connector can mate with Neutrik XLR based network cables and standard RJ45s This should be connected to a PoE enabled switch...

Страница 14: ...he AoIP22 to be updated Please see the Updating Firmware section of this handbook for more information 6 Micro USB Connector The Micro USB connector is used for connecting the AoIP22 to a PC when upda...

Страница 15: ...N ANALOGUE TO DIGITAL CONVERTER DIGITAL TO ANALOGUE CONVERTER AUDINATE ULTIMO CHIPSET MICROPROCESSOR Control Data Control Data Control Data I2S Audio I2S Audio NETWORK PHY ANALOGUE AUDIO OUT DANTE AES...

Страница 16: ...tware from Audinate This can be downloaded by visiting Audinate s web site at www audinate com Connecting AoIP22 To the Network The AoIP22 can be connected to the network that you are going to use for...

Страница 17: ...ory name is AOIP22 sn 105 903ef5 Where AOIP22 sn 105 refers to the Glensound product and its serial number and 903ef5 refers to its MAC address Dante Controller TIP If you have never run Dante control...

Страница 18: ...interface and are unfortunately not able to provide full AES67 support for the unit AES67 support should be sought directly from Audinate 1 Turning On AES67 Mode If you want to use your AoIP22 on an A...

Страница 19: ...is done by selecting the Create New Multicast Flow Icon in the Device View Tick the AES67 Flow check box then select up to 8 channels to be included in the flow then click Create The AoIP22 only has...

Страница 20: ...Non redundant Destination address in range 239 nnn 0 0 to 239 nnn 255 255 239 nnn 16 port 5004 48kHz sampling rate 24 bit linear L24 encoding 1 msec packet time Up to 8 channels per stream Received AE...

Страница 21: ...ing new firmware on to the AoIP22 It can be downloaded from the STMicroelectronics website found here https goo gl AbzhsA It is the file named STSW STM32080 Once you have downloaded this file you will...

Страница 22: ...lease the reset button Your PC should make an audible sound when this process is successful as windows is detecting a new USB device 5 Loading the firmware Now open DfuSe Demo If the AoIP22 successful...

Страница 23: ...irmware to put on to the AoIP22 Click choose and then select the dfu file that you downloaded from the Glensound website This will be located in your downloads folder by default If the file loads succ...

Страница 24: ...e AoIP22 firmware The firmware is now ready to be put on to the AoIP22 Tick the Verify after download box first and then click Upgrade Click yes to proceed Figure 6 Upgrade Figure 7 Start upgrade Figu...

Страница 25: ...show the status of the operation If the operation was successful DfuSe Demo will report that Targery 00 Verify Successful You may also see that it will report how much data was successfully transferre...

Страница 26: ...Page 26 of 29 7 Final steps Now click Leave DFU mode to finish the procedure You may now disconnect the USB cable and continue to use the AoIP22 with the freshly updated firmware Figure 10 Final step...

Страница 27: ...The Product Version shows the currently installed version of Ultimo Chipset dnt code 2 Finding Out What The Latest Available Version Is Go the AoIP22 s web and open the Firmware Latest Version Tab Th...

Страница 28: ...RCA Phono or D type connector Domestic devices generally work on different audio levels than professional devices such as ours This may mean that the output of the AoIP22 seems a little high and the...

Страница 29: ...alogue In Out 0dBu 20Hz to 22k 0 25dB 20 k 18dBu 0 0013 THD N 1kHz Reference to 18dBu output Electronically balanced can be wired Unbalanced on Neutrik 3 pin XLR socket Neutrik RJ45 EtherCON 44 1k 48k...

Отзывы: