IMPORTANT:  All  clearances  listed  are  the 

MINIMUM  required  and  must  be  strictly 

followed. 

 

This  appliance  is  certified  for  installation  on  a 

solid  combustible  surface,  such  as  a  wood  floor, 

vinyl or carpeting. 

 

The  following  pages  provide  diagrams  for  safe 

clearances to combustibles.  

••••    

To  clean  the  stove,  make  sure  the  appliance 

is off and cold.  Remove the logs and embers.  

The  logs  must  be  handled  with  extreme 

care,  they  are  fragile.    Use  a  vacuum  to 

clean  burner  and  air  openings  in  the  bottom 

and  back  of  the  appliance.  Carefully  replace 

the logs and embers.

 

• 

Fire Extinguisher: Every home should have at 

least  one  fire  extinguisher.    An  approved 

Class A-B-C extinguisher should be mounted 

on  the  wall  near  an  exit  and  close  to  the 

appliance,  but  not  so  close  that  accessibility 

to the extinguisher could be  

blocked by a 

fire.  Your  local  Fire  Department  can  advise 

you concerning the most appropriate location. 

••••    

Smoke  Detectors  &  Carbon  Monoxide 

Detectors: Install at least one smoke detector 

on  each  floor  of  your  home  to  ensure  your 

safety.    It  should  be  located  away  from  the 

gas  appliance  and  close  to  the  sleeping 

areas.  Follow  the  smoke  detector 

manufacturers  placement  installation  and 

maintenance  instructions.  Your  local  Fire 

Department  may  provide  assistance  in 

selecting  smoke  detectors  and  CO-detectors. 

It  is  strongly  recommended,  for  your  family’s 

protection, that a CO-detector be placed in all 

homes that utilize gas in any form.  

 

• 

The appliance vent should be enclosed when 

installed  in  or  passing  through  a  living  area, 

where children may come in contact with it. 

• 

Only vent terminations specified may be used 

with this stove. 

• 

Venting terminals shall not be recessed into a 

wall or siding. 

1)  Wear  gloves  and  safety  glasses  for 

protection. 

2)  Exercise extreme caution when using ladders 

or when on roof tops. 

3)  Be  aware  of  electric  wiring  locations  in  walls 

and ceilings. 

4)  Use  a  back  support  when  doing  any 

heavy lifting. 

GENERAL SAFETY (HOMEOWNER) 

VENTING SAFETY  

Please note the following key points 

regarding the location of your appliance: 

• 

A sufficient gas pressure is required to supply 

the unit with a minimum inlet pressure 

• 

Allow adequate accessibility clearances for 

servicing and proper operation. 

• 

Allow adequate clearance to combustibles. 

• 

Consider the termination location.   

• 

A suitable power outlet is required to provide 

power to the fan. 

PLANNING YOUR INSTALLATION 

CLEARANCES TO COMBUSTIBLES  

Installation Instructions—Safety 

FOR THE INSTALLER 

Ensure,  as  in  any  installation,  that  structural 

members  are  not  cut  or  weakened  during 

installation . 

 

 

When  installing  the  appliance  in  a  mobile or 

manufactured  home,  it  must  be  securely 

anchored to the floor by means of the anchor 

provided in the mobile home kit.  Also ensure 

that proper grounding is provided by using a 

#8 grounding lug, wire and a star washer. 

Содержание Masport Geneva2

Страница 1: ...e gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installa...

Страница 2: ... Instructions 5 Specifications 6 Warnings Caution and Safety Notices 7 Installation Instructions Safety 8 Planning Your Installation 8 Clearances To Combustibles 9 Rear Vent Snorkel Installation 9 Top Vent Venting Diagrams 10 Horizontal Termination Installation 11 Vent Restrictor Use And Installation 12 Vertical Termination Installation 12 Basements Installations 12 Through Roof Termination 13 Sei...

Страница 3: ...ndicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Thank you for purchasing a Masport gasfire and welcome to the Masport family Your new Masport gasfire will give you many hours of warmth and comfort Please make sure you take a few minutes to read this owner s manual It explains the steps required to safely assemble install operat...

Страница 4: ...ertification label is provided here for your review Due to constant up grades it is possible that the information shown here may not coincide with the label as at tached to the unit In the event of a discrepancy between the labels the label on the unit is con sidered as the correct one ...

Страница 5: ...Masport Geneva2 Owners Installation and Operation Manual Page 5 Lighting Instructions ...

Страница 6: ...ssure low 0 37 kPa 0 87 kPa Min Supply Pressure for Purpose of Input Adjustment 1 2 kPa 3 0 kPa Max Supply Pressure for Purpose of Input Adjustment 3 5 kPa 3 5 kPa Orifice Size 37 DMS 53 DMS Nominal Input Rating 29 5 MJ h 28 MJ h Primary Air Opening 3mm Minimum 3mm Minimum Electrical Rating 240 V A C System 240 V A C System Circulating fan Variable Speed Variable Speed Vent System 100 x 170 mm 100...

Страница 7: ...LIANCE MUST BE VENTED TO THE OUTSIDE ONLY THIS APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE DO NOT USE THIS HEATER IF ANY PART HAS BEEN UNDER WATER IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE HEATER AND TO REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER Warnings Caution IF THIS APPLIANCE I...

Страница 8: ...smoke detectors and CO detectors It is strongly recommended for your family s protection that a CO detector be placed in all homes that utilize gas in any form The appliance vent should be enclosed when installed in or passing through a living area where children may come in contact with it Only vent terminations specified may be used with this stove Venting terminals shall not be recessed into a ...

Страница 9: ...em may terminate in one of two ways Vertical termination using a vent cap or Horizontally using a wall termination There are limitations to the vertical and or horizontal lengths When calculating the length of the vent pipe from the outlet of the appliance to termination allow for ceiling thickness vertical rise in the attic or second story and sufficient vertical height above the roof Fire stops ...

Страница 10: ...Masport Geneva2 Owners Installation and Operation Manual Page 10 ...

Страница 11: ...m clearance of 50mm to combustibles must be maintained around the vent pipe on horizontal pipe runs and 25mm on vertical runs Installation Instructions 00 8 40 2 25 2 2 25 25 2 2 22 2 2 92 A 3 0 0 8 B 0 Horizontal Wall Vent Terminations C L C L Center of hole 250mm square 5 8 8 C0 C0 C ...

Страница 12: ...mm Collar attached to unit Restrictor Vertical Installations 2 2 D 5 2 5 6 7 5 95 0 8 Basement Installations 0 400 5 8 Drainage Minimum 300mm NOTE ALWAYS CHECK YOUR LOCAL CODES BEFORE INSTALLING VENTING NECESSARY CLEARANCES AND REQUIRMENTS MAY VARY Installation Instructions Restrictor Sizes ...

Страница 13: ...adequate heat shield protection is provided Consult local codes for minimum vent cap height above the roof vent must be a minimum 50mm from any wall Termination Above Roof To prevent water seepage install the flashing with upper portion slid under the roofing material and the lower portion over the roofing material Note Do not fasten down until the final adjustments to the vent have been made Inst...

Страница 14: ... 0 96 ECB 0 96 ECB C 4 6 4 44 B 4C 6B 4 6E 46 Height Typical vent Installation F 44 A G 5 6 7 8 Installation Instructions Seismic Restraint New Zealand Regulations require that flued gas heaters be secured to prevent shifting in the event of an earthquake This is done by fastening the heater to the floor right through the floor protector if one is fitted Fasten with two screws not less than 6mm di...

Страница 15: ...Masport Geneva2 Owners Installation and Operation Manual Page 15 ...

Страница 16: ...00 0 1 2 2 3 3 3 2 GAS SUPPLY INSTALLATION Installation Instructions Gas Supply 3 4 3 5 1 2 1 6 4 6 2 4 3 4 1 5 4 2 3 4 3 6 5 3 3 7 8 3 5 3 3 5 3 3 4 3 3 1 5 8 5 3 9 3 5 5 5 8 3 5 3 3 5 3 4 3 4 3 3 3 4 2 3 3 3 2 1 5 1 3 3 3 6 6 3 3 3 3 7 8 3 5 3 5 3 3 5 3 3 5 5 5 3 3 3 6 Pedestal Cover Removal 6 8 5 5 6 ...

Страница 17: ... gas leak detector Do not use open flame for leak detection 6 0 00 0 3 4 Installation Instructions 6 FACTORY SETTING Natural Gas 3 0 mm Open LP GAS 3 0 mm Open CAUTION Parts requiring adjustment during operation may be hot Open Soft blue flame Closed tall yellow flame 8 AERATION ADJUSTMENT PIPING DETAIL 9 I 9 9 A 8 3 C Flame Picture ...

Страница 18: ...lve connections 6 1 5 Geneva2 LOGSET INSTALLATION THERMOSTAT WARNING The gas valve of this appliance operates on a millivolt system and is not intended to be connected to any other power source 8 0 E 0 WARNING Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounde...

Страница 19: ...CIRCUIT Snap Disc MILLIVOLT CIRCUIT Chordset Ground Blower Control Circulation Fan 3 1 Wiring Diagrams Pilot Assembly Thermocouple Thermopile Pilot Gas Line Thermostat leads or leads to optional remote thermostat Thermostat On Off Rocker Switch TH THTP TP Honeywell Gas Valve ...

Страница 20: ...s control system which has been under water DO NOT Use this appliance if you smell gas WHAT TO DO IF YOU SMELL GAS OPEN WINDOWS DO NOT TOUCH ANY ELECTRICAL SWITCH DO NOT USE THE PHONE IN YOUR BUILDING EXTINGUISH ANY OPEN FLAME IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE AND FOLLOW THE GAS SUPPLIER S INSTRUCTIONS IF YOU CANNOT REACH YOUR GAS SUPPLIER CALL THE FIRE DEPARTMENT Operatin...

Страница 21: ...be visible Check to make sure that venting is secure Check all external parts such as grills doors and control cover are properly attached and fastened CAUTION Do not turn the unit off and on again without a minimum of a 60 second wait between firing Make sure you read this entire manual especially the lighting instructions on page 5 before you begin stove operation Keep in mind that your thermost...

Страница 22: ...is due to the expansion and contraction of the steel in the firebox BLOWER We use high efficiency fans in our appliances You may hear a whirring sound when the fan turns on This will decrease or increase depending on the speed setting of the fan PILOT FLAME You may detect a very slight whisper sound from the pilot when it is turned on These are all normal sounds associated with this type of applia...

Страница 23: ... flows around the thermopile one around the thermocou ple and one flows over the burner See page 26 for further pilot instructions GAS VALVE REPLACEMENT 1 Disconnect electricity to the appliance 2 Shut off the gas to the appliance and disconnect the gas line to the appliance 3 If the appliance has a remote switch or thermostat disconnect the wires at the front of the valve 4 Undo the four screws h...

Страница 24: ...there is any sign of wear VIEWING GLASS REPLACEMENT This appliance is supplied with high temperature 5mm high temperature ceramic glass that will easily withstand the heat your unit was designed to produce In the event the glass breaks contact your dealer or MASPORT to arrange for your glass to be replaced repaired REMOVING THE BLOWER 1 Turn the gas off to the unit 2 Turn off unplug the electric s...

Страница 25: ... kit 9 Replace in reverse The model Geneva2 is designed to burn either Natural Gas or LPG Fuel Each heater leaves the factory equipped for one specific fuel but it is a simple opera tion to convert the heater to an alternate fuel in the field The original fuel type is marked on the rating label NATURAL GAS LPG LEAK TESTING CAUTION DO NOT TEST FOR LEAKS WITH AN OPEN FLAME With the main burner ON te...

Страница 26: ...Masport Geneva2 Owners Installation and Operation Manual Page 26 Troubleshooting 1 8 5 3 6 3 8 8 9 5 0 L H 0 0 7 A 8 8 H 5 60 60 ...

Страница 27: ...2 2 2 A2 2 2 A 2 D 2 O O 5 25 2 2 2 2 2 M 9 C 2 M0 0 2 A 5 1 A 25 A N 2 1 A 2 5 2 2 N 2 25 A 2 2 2 2 A 2 2A 5 6 2 2 2 2 2 A 5 5 A 2 2 2 2 2A 2 A 5 22 2 22 5 2 2 2 1 A 96 5 E9 CO 5 25 A 2 2 2 2 A 2 2A 5 2 2 A 2 2 2 2A 1 A A A A A A2 A 2 2 2 2 2 A2 2 2 2 2 2 A 5 5 A 2 2 2 2 2A 2 A 5 22 2 ...

Страница 28: ...e 09 274 8265 Fax 09 274 8472 Email sales glendimplex co nz Web www masportheating co nz Customer Hotline 0800 655 001 Distributed in Australia by Glen Dimplex Australia Pty Limited Unit 2 205 Abbotts Road Dandenong South Victoria 3175 Phone 1 300 566 816 Fax 03 8787 3570 Email sales glendimplex com au Web masportheating com au Manufactured in Canada by Valley Comfort Systems Inc 1290 Commercial W...

Отзывы: