Masport Geneva
2
Owners Installation and Operation Manual
Page 23
Thermopile
Thermocouple
Pilot for
Burner ignition
FREQUENCY OF SERVICE
Regularly:
♦
♦
D
8
♦
+
♦
♦
Once a Year:
♦
2
&
&
♦
#
+
Have a qualified service technician:
♦
♦
"
♦
♦
VENTING:
1. Check the venting system for any signs of
corrosion.
2. Remove the vent termination and check the inside
of the vent by shining a light down the pipe.
3. Inspect pipe seams and joints and ensure they are
still tight.
4. Check wall straps and all vent supports.
♦
LOGS:
1. Check logs are correctly positioned (see installation
instructions).
2. Check there are no cracked logs.
3. Clean off any soot deposits using a soft brush.
NOTE: Incorrect log positioning may cause carbon
build up and discoloration. This may void the
warranty.
TECHNICAL INSTRUCTIONS
♦
PILOT ASSEMBLY: The correct flame pattern
should have three strong blue flames. One flows
around the thermopile, one around the thermocou-
ple and one flows over the burner. See page 26 for
further pilot instructions
GAS VALVE REPLACEMENT:
1. Disconnect electricity to the appliance.
2. Shut off the gas to the appliance and disconnect the
gas line to the appliance.
3. If the appliance has a remote switch or thermostat,
disconnect the wires at the front of the valve.
4. Undo the four screws holding the valve plate to the
pedestal assembly.
5. Gently rotate the valve to gain access to the
millivolt wiring, pilot tube nut and burner supply tube
nut.
6. Carefully undo the pilot and burner supply tubes
and remove the valve.
7. Replacing the assembly is the reverse of the above
instructions.
Maintenance
CAUTION: NEVER CLEAN THE APPLIANCE WHEN IT IS HOT. ANY SAFETY SCREEN OR
GUARD REMOVED FOR SERVICING MUST BE REPLACED PRIOR TO OPERATING THE
APPLIANCE. DO NOT USE ANY SUBSTITUE MATERIALS.
REMOVING THE BURNER ORIFICE
1. Use a 1/2” wrench to loosen and remove the burner
orifice.
2. Change the orifice.
Pedestal Cover Removal
#
#
6
#
8
5
5
#
6