![Glen Dimplex 16CHCIAOC6 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/glen-dimplex/16chciaoc6/16chciaoc6_installation-and-operating-instructions-manual_2231467037.webp)
www.gdts.one
DOK4x HCIAO CxDEN · FD 9912
35
Air-to-water heat pump 16 kW with cooling and domestic hot water
English
Information requirements for heat pump space heaters and heat pump combination heaters
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Tj = - 7°C
P
dh
8,0
kW
Tj = - 7°C
COP
d
2,36
-
Tj = + 2°C
P
dh
5,6
kW
Tj = + 2°C
COP
d
3,41
-
Tj = + 7°C
P
dh
6,6
kW
Tj = + 7°C
COP
d
4,28
-
Tj = + 12°C
P
dh
7,7
kW
Tj = + 12°C
COP
d
5,35
-
Tj = bivalent temperature
P
dh
9,4
kW
Tj = bivalent temperature
COP
d
2,10
-
Tj = operation limit temperature
P
dh
9,4
kW
Tj = operation limit temperature
COP
d
2,10
-
For air-to-water heat pumps
For air-to-water heat pumps:
Tj = -15°C (if TOL < -20°C)
P
dh
-
kW
Tj = -15°C (if TOL < -20°C)
COP
d
-
-
Bivalent temperature
T
biv
-10
°C
For air-to-water heat pumps:
Operation limit temperature
TOL
-10
°C
Cycling interval capacity for heating
P
cych
-
kW
Cycling interval efficiency
COP
cyc
-
-
Degradation co-efficient (**)
C
dh
0,99
-
Heating water operating limit
temperature
WTOL
60
°C
Power consumption in modes other than active mode
Supplementary heater
Off mode
P
OFF
0,025
kW
Rated heat output (*)
P
sup
0
kW
Thermostat-off mode
P
TO
0,026
kW
Type of energy input
eletrical
Standby mode
P
SB
0,026
kW
Crankcase heater mode
P
CK
0,000
kW
Other items
Capacity control
variable
-
3800
m³ /h
Sound power level, indoors/ outdoors
L
WA
45/55
dB
-
--
m³ /h
Emissions of nitrogen oxides
NO
x
-
mg/kWh
Declared load profile
XL
Water heating energy efficiency
η
wh
89
%
Daily electricity consumption
Q
elec
8,86
kWh
Daily fuel consumption
Q
fuel
-
kWh
Contact details
(**) If C
dh
is not determined by measurement nthen the default degradation is C
dh
= 0,9
(--) not applicable
Model
16IHCIAOC6
Air-to-water heat pump
yes
Water-to-water heat pump
no
Brine-to-water heat pump
no
Low-temperature heat pump
no
Equipped with a supplementary heater
yes
136
%
Heat pump combination heater
yes
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low- temperature heat pumps, parameters
shall be declared for low-temperature application.
Rated heat output (*)
Prated
9
kW
Seasonal space heating energy
efficiency
η
s
Parameters shall be declared for average climate conditions:
For air-to-water heat pumps: Rated
air flow rate, outdoors
For water-/brine-to-water heat
pumps: Rated brine or water flow
rate, outdoor heat exchanger
Declared capacity for heating foer part load at indoor temperature 20°C and
outdoor temperature T
j
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature T
j
For heat pump combination heater:
Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach
(*) For heat pump space heaters and heat pump combination heaters, the rated output P
rated
is equal to the design load for heating P
designh
, and the rated
heat output of a supplementary capacity for heating sup(
Tj
).
Содержание 16CHCIAOC6