
Mod: P9(**)F25
(Fig. 31)
1. Triple-crown burner (TC)
2. Fish Kettle burner (P)
3. DUAL burner (DUAL)
90cm hob with side
commands
Mod: P9(**)L-5
(Fig.32)
1. Auxiliary burner (A)
2. Rapid burner ( R )
3. Semi-rapid left back burner (SR)
4. Semi-rapid right front burner (SR)
5. Triple-crown burner (TC)
Mod: P9(**)L28
(Fig.33)
1. Auxiliary burner (A)
2. Rapid burner ( R )
3. Semi-rapid left back burner (SR)
4. Semi-rapid right front burner (SR)
5. Triple-crown burner (TC)
6. Electric plate ø 145
Mod: P9(**)L-B
(Fig.34)
1. Auxiliary burner (A)
2. Fish Kettle burner (P)
3. Semi-rapid left back burner (SR)
4. Semi-rapid right front burner (SR)
5. Triple-crown burner (TC)
Mod: P9(**)L23
(Fig.35)
1. Auxiliary burner (A)
2. Fish Kettle burner (P)
3. Semi-rapid left back burner (SR)
4. Semi-rapid right front burner (SR)
5. DUAL burner (DUAL)
Mod: P9(**)L-C
(Fig.36)
1. Auxiliary burner (A)
2. Electric plate ø 180
3. Semi-rapid left back burner (SR)
4. Semi-rapid right front burner (SR)
5. Rapid burner ( R )
6. Electric plate ø 145
Mod: P9(**)L-7
(Fig.37)
1. Auxiliary burner (A)
2. Electric plate ø 145
3. Semi-rapid left back burner (SR)
4. Semi-rapid right front burner (SR)
5. Rapid burner ( R )
Mod: P9(**)L27
(Fig.38)
1. Auxiliary burner (A)
2. Electric plate ø 180
3. Semi-rapid left back burner (SR)
4. Semi-rapid right front burner (SR)
5. Rapid burner ( R )
USING THE HOB
Gas burners
The flow of gas to the burners is regulated by the knobs shown in fig.41 which command the valves. Depending
on the chosen version, the symbols can be printed onto the knobs or the command panel. The following
regulations are obtained when the indicator points to the printed symbols:
Valve closed, no gas flow
Maximum capacity, maximum gas flow
Minimum capacity, minimum gas flow
Switching on the burners
- Burners without safety valves
To turn on burners without electric ignition, or when there is no electrical power in models with ignition, place a
flame near to the upper part of the burner, press and turn the knob anti-clockwise so that it points to the
ҝ
symbol with the reference on the panel.
Turn the knob to the small flame for minimum capacity.
All working positions must be chosen between the maximum and minimum and never the maximum and
switch-off point.
To turn the burner off, turn the knob clockwise until it reaches position
“valve closed”
4
Содержание P6140FV
Страница 2: ......
Страница 15: ...Fig 1 1 Fig 2 1 2 Fig 3 1 Fig 4 1 2 Fig 6 Fig 5 Fig 7 1 2 1 1 13 ...
Страница 16: ...Fig 10 1 2 4 3 Fig 11 1 2 4 3 Fig 12 1 2 4 3 Fig 8 Fig 9 14 ...
Страница 19: ...Fig 29 3 2 1 Fig 30 3 2 1 Fig 31 3 2 1 17 ...
Страница 21: ...Fig 39 Fig 40 Fig 41 Fig 42 19 ...
Страница 22: ...Fig 43 Fig 44 Fig 45 Fig 46 Fig 47 Fig 48 Fig 49 20 ...
Страница 23: ...Fig 50 Fig 51 Fig 52 Fig 53 Fig 54 21 ...
Страница 24: ...Fig 55 Fig 56 Fig 57 22 ...
Страница 25: ...23 ...
Страница 26: ...24 ...
Страница 27: ......
Страница 28: ...CODE H01A393G ...