Page 10
Torrent GreenHeat OV
Basic Appliance
1. Open vent - 22mm comp
2. Overheat
stat
3. Plate heat exchanger fl ow - 22mm
4. Domestic hot water store sensor
5. Immersion
heater
6. Solid fuel fl ow - 28mm comp
7. Hot water supply - 22mm comp
8. OV boiler fl ow - 22mm comp (350/450 - 28mm comp)
9. Central heating fl ow - 22mm comp
10. Control stat
11. Cold mains supply - 22mm comp
12. Cold feed - 15mm comp
13. Immersion heater
14. Plate heat exchanger return - 22mm
15. Central heating return - 22mm comp
16. OV boiler return - 22mm comp (350/450 - 28mm comp)
17. Solid fuel return - 28mm comp
Component kit supplied attached
A. Thermostat
Optional extra components
A. Header
tank
B. Ball
valve
C. Float
D. Immersion
heater
E. Overheat
thermostat
Torrent GreenHeat SP
Basic Appliance
1. Open vent - 22mm comp
2. Overheat
stat
3. Plate heat exchanger fl ow - 22mm
4. Domestic hot water store sensor
5. Solid fuel fl ow - 28mm comp
6. Hot water supply - 22mm comp
7. Central heating fl ow - 22mm comp
8. Immersion
heater
9. Control
stat
10. SP coil fl ow - 22mm comp (250/350 - 28mm comp)
11. Cold mains supply - 22mm comp
12. Cold feed - 15mm comp
13. SP coil return - 22mm comp (250/350 - 28mm comp)
14. Plate heat exchanger return - 22mm
15. Central heating return - 22mm comp
16. Solid fuel return - 28mm comp
Component kit supplied attached
A. Thermostat
Optional extra components
A. Header
tank
B. Ball
valve
C. Float
D. Immersion
heater
E. Overheat
thermostat
2
9
8
10
13
15
16
17
6
5
3
1
7
11
12
14
4
2
7
8
9
10
13
15
16
5
3
1
7
11
12
14
4
DESIGN
SYSTEM DESIGN
Typical arrangement of tappings shown on the appliance, but these can be
adjusted to suit specifi c installation requirements.
The feed and expansion tank must be sized to take the water expansion of the
whole system (i.e. solid fuel boiler, open vented boiler and auxiliary heating).