Page 29
INSTALLATION
WIRING DIAGRAMS
Store stat
ON OFF
C
1
2
ng
PRV
Solar
pumping
station
Solar panels
S1
S1 : Solar flow temperature sensor
S2 : Solar zone store temperature sensor
S3 : Store overheat temperature sensor/Thermostat
P1
S2
S3
Torrent GreenHeat SOL
E
C
NC
Solar controller
Overheat
thermostat
(S3)
L N E L N E S2 S1
Solar
Pump
230Vac
50Hz
supply
SL
E C 1 2
on
off
NOTE
Some solar controllers, the overheat protection is provided by a temperature sensor,S3,
which is wired directly to the solar controller same as sensors S1 and S2
In this case the mechanical overheat thermostat (S3) shown in this diagram is not required and
the solar pump is wired straight to the solar controller.
Boiler hold off pipe thermostat
Type LL641B1012
Temperature range: 50 – 95
o
C
Boiler hold off pipe thermostat
Type LL641B1012
Temperature range: 50 – 95
o
C
NOTE
As part of system setup and commissioning, it is important that this boiler hold-off pipe thermostat
be adjusted to find the best setting for each individual installation.
Failure to do so will give under performance of either the boiler or the solar heating system
Содержание Torrent GreenHeat HP TGH170-HP