Page 3
Manufacturer: Gledhill Building Products Ltd
Max. mains inlet water pressure
5.0bar
Max. working pressure - Primary heat exchanger (Indirect models) 3.0bar
Max. working pressure - Solar heat exchanger (Solar models)
6.0bar
Max. working pressure - Open vented thermal store (All models) 10.0m (1.0bar)
Max. working pressure - Open vented central heating system
10.0m (1.0bar)
Max. working pressure - Sealed heating system
3.0bar
Immersion heater rating
3kW @ 230V ac, 50Hz
The Torrent has comes complete with plate heat exchanger. This has a very
small volume of water held within it, therefore any minimal expansion will be
accomodated in the supply pipe.
Handling Before Installation
The Torrent must be handled with care and stored the correct way up in a dry place.
Any manual handling/lifting operations will need to comply with the requirements
of the Manual Handling Operations Regulations issued by the H.S.E. The appliance
can be moved using a sack truck on the rear face although care should be taken and
the route should be even. In apartment buildings containing a number of storeys we
would recommend that the appliances are moved vertically in a mechanical lift. If it
is proposed to use a crane, expert advice should be obtained regarding the need for
slings, lifting beams etc. A specifi c manual handling assessment is shown in Appendix
B at the rear of this manual.
Maintenance
Modifi cations should not be made to this product. Replacement parts, including
immersion heaters, should be purchased from Gledhill Building Products Limited, or
agents approved by them. The manual must always be left with the Torrent.
Note:
The cylinder is factory fi tted with immersion heaters with thermal cut outs. Immersions
without thermal cut outs must not be fi tted.
DESIGN
DESCRIPTION
Содержание Torrent GreenHeat HP TGH170-HP
Страница 48: ...Page 48 BENCHMARK ...
Страница 49: ...Page 49 BENCHMARK ...