Glastender, Inc.  •  5400 North Michigan Road  •  Saginaw, MI  •  48604-9720

800.748.0423  •  989.752.4275  •  Fax 989.752.4444  •  www.glastender.com

2

t

roubLe

 S

hooting

 t

he

 S

oDa

 S

yStem

 

C

onDition

 

C

auSe

 

r

emeDy

 

 

1. No soda or water at valve.

 

(a).  Water supply interrupted. 

 

(a). Check if valve open.

 

 

 

 

(a). Check water pressure

 

(b).  Frozen water bath. 

 

(b). Replace ice bank control.

 

(c).  Valve power interrupted. 

 

(c). Check electrical circuit.

2. No syrup at valve.

 

(a).  Product tank or BIB        

 

(a). Re-connect.                

      

 

connector not in place. 

 

(b).  Low CO2 gas pressure. 

 

(b). Replace cylinder.

 

(c).  Tank dip tube “O” ring. 

 

(c). Return tank to bottling plant.

3. No Carbonation.

 

(a).  CO2 gas supply depleted 

 

(a). Replace cylinder.

      

 

(tank volume gauge in the red). 

 

(a). Replace cylinder.

 

(b).  Carbonator unit not operating. 

 

(b). Consult Service Tech.

4. Product foaming on one valve.

 

(a).  Booster gas pressure too high. 

 

(a). Re-adjust.

 

(b).  Syrup supply almost depleted. 

 

(b). Replace tank or BIB.

 

(c).  Brix too heavy. 

 

(c). Adjust brix.

5. Product foaming on all valves.

 

(a).  Booster gas pressure too high. 

 

(a). Re-adjust.

        

 

(Common regulator) 

 

(b).  Product tanks or BIB stored 

 

(b). Product tanks or BIB  

 

 

 

in cold ambient temperature    

             should be stored in room      

 

 

and are absorbing CO2. 

              be stored in room temperature.

t

roubLe

 S

hooting

 t

he

 r

efrigeration

 S

yStem

 

C

onDition

 

C

auSe

 

r

emeDy

 

 

1. Refrigeration unit not operating.

 

(a).  Power supply interruption.

       

 

• Blown fuse. 

• Replace

       

 

• Circuit or area-wide failure. 

• Check power plug and outlet.

 

(b).  Compressor will not start. 

 

 

 

• Defective overload protector. 

• Check, and replace if necessary.        

 

 

• Defective starter relay 

• Check, and replace if necessary.

        

 

• Internal motor winding fault  

• Replace compressor.  

 

(c).  Condenser fan not running.

      

 

(Should operate with compressor)

        

 

• Wiring connection fault. 

• Check circuit and repair.

        

 

• Burnt motor winding. 

• Replace motor. 

2. Refrigeration unit operates but 

 

(a).  Condenser is plugged with dirt. 

(a).  Clean with a brush.

    

does

 

not cool.

 

  

  

 

(b).  Freon gas leak, (gauge shows 

(b). Locate and repair.

        

 

vacuum pressure reading on suction side). 

 

(c).  Agitator motor not operating (should

 

 

run continuously). 

 

 

       

 

• Shaft jammed. 

• Adjust alignment.

       

 

• Wiring connection fault. 

• Check  circuit and repair.

      

 

• Burnt motor windings. 

• Replace motor.

3. Water bath frozen.

 

• Defective cold control. 

• Replace control.

4. Noise in water bath.

 

• Water level too low in water bath. 

 

• Fill to proper level.

t

roubLe

 S

hooting

Содержание LC66-6-LEV

Страница 1: ...0 North Michigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 989 752 4444 www glastender com LC66 Pre Mix Post Mix and Juice Pro Dispensers Sprint Counter Top Dispensers 2007 Glastender I...

Страница 2: ...lly will not be reimbursed under warranty Condenser coils on self contained refrigeration products must be cleaned regularly Failure to provide adequate air flow to a refrigeration unit will void the...

Страница 3: ...Assurance Tips 3 Specifications 4 Wiring Diagram 4 Parts Directory 5 6 Typical Installation Diagram 7 Installation Notes 8 Index Glastender Inc 5400 North Michigan Road Saginaw MI 48604 9720 800 748 0...

Страница 4: ...there is less than 20 p s i 1 4kp cm2 install a water pressure regulator 4 Recommended gas pressure 80 p s i 5 6 kp cm2 5 Connect power upon completion Gas Connections 1 Mount regulator to wall or cy...

Страница 5: ...r BIB stored b Product tanks or BIB in cold ambient temperature should be stored in room and are absorbing CO2 be stored in room temperature Trouble Shooting The Refrigeration System Condition Cause R...

Страница 6: ...will dilute the drink causing a weak flat tasting beverage Check Carbonation A constant supply of CO2 at the correct pressure will ensure proper quality Taste Always taste the finished drink before se...

Страница 7: ...nit for maximum air flow and a minimum of 12 above unit for servicing Compressor failure due to inadequate ventilation will void the warranty Dimensions Height 19 06 48 41 cm Illumination Add 3 50 8 8...

Страница 8: ...lastender Inc 5400 North Michigan Road Saginaw MI 48604 9720 800 748 0423 989 752 4275 Fax 989 752 4444 www glastender com 5 LC66 Compressor and Related Parts 2 1 3 11 12 8 7 9 10 15 16 17 14 13 4 6 5...

Страница 9: ...GT 034204 Transformer 37 00 6 09000306 GT 033422 Locking switch 30 53 7 06001439 GT 035014 Compressor 1 3 HP 435 00 8 09000295 GT 032623 Condenser Coil 101 00 9 09000338 GT 035116 Agitator Motor 170 0...

Страница 10: ...Glastender Inc 5400 North Michigan Road Saginaw MI 48604 9720 800 748 0423 989 752 4275 Fax 989 752 4444 www glastender com 7 Typical Installation Diagram Installation Schematic for LC66...

Страница 11: ...___________ _________________________________________________________________________________________ _________________________________________________________________________________________ ________...

Страница 12: ......

Отзывы: