background image

8

Parts required to join Two (2) Cabinets:

Cabinet 

Connector 

screws 

Qty 

screw   Qty

depth

Part#

Qty

Caps

4” deep

#426

2

10-32 x 1 1/2” 8

#434

8

6” deep

#429

2

10-32 x 1 1/2” 8

#434

8

Left Top

Right Top

Section 1- Top View

Front Cabinet Flanges meet here

Combining Two (2) or Three (3) 
Cabinet Units before Installation.

Any of the cabinets that are the same height may be joined to form
one unit. Follow these instructions to create the final size unit before
attempting installation. 

For Multiple Cabinets:

Two or Three unit cabinets must be

joined as shown before installation.

Note: Three cabinet units require an additional installation
screw in the top center of the center unit. drill an access hole in
the cabinet and install an additional #10 x 1 1/2” wood screw.
Cover the screws with four or five screw caps (part #434).

• Be sure to determine the hinge side door swing location for
each unit.

• 

YoU MUsT oRdeR A leFT oR RIGHT HANded dooR AT THe

TIMe oF oRdeR FoR All MIRRoRed CABINeT eleCTRIC oP-
TIoN UNITs.

• Mark the top of each unit-- Left, Right or Center with the Hinge
plates in the proper position.

When the unit is fully assembled refer to “R.o.” formula chart on page
7 to determine the R.o. required for the unit as assembled.

Assembling multiple cabinet units:

1. Place the units on a 2x4 or 2x6 stud of sufficient horizontal length to
support all the units being joined. Place 4” edge of the stud flat on the
floor with the cabinet facing up and the bottom flush to the inside edge
of each 2x4. 
2. Install the Cabinet Connector (part #426 or 429) on the outside of
the left hand cabinet. Use the pre-punched holes immediately above
and below the hinge plate locations. Use screws 10-32 x 1/2” as sup-
plied. (see section #1)
3. Move the second cabinet into position so that the face flange of both
units are aligned. Fix the cabinets together using screws 10-32 x 1/2”
as supplied. (see section #1).
4. If there is a third unit repeat the steps above

.

WARNING: Units are not intended to be interconnected
electrically. Each Mirrored Cabinet with Electric Option 
requires its own independent connection to junction box.

Parts required to join Three (3) Cabinets:

Cabinet 

Connector 

screws 

Qty 

screw   Qty

depth

Part#

Qty

Caps

4” deep

#426

4

10-32 x 1 1/2” 16

#434 16

6” deep

#429

4

10-32 x 1 1/2” 16

#434 16

Center Top

Left Top

Right Top

Shown here -- 
Left, Left and Right 
hinge side door swings

Left Top

Right Top

Shown here --

Left and Right 

hinge side door swings

Содержание GC1630

Страница 1: ...tric wiring must be by a licensed electrician Recessed or wall mounted installations to be performed by a professional installer See pages 7 through 10 of this manual This unit s electrical connection...

Страница 2: ...r 14 15 Warranty 16 Unpack all parts carefully and protect Glass and Mirror parts during installation Carefully review all parts and read the installation instruction before you start Please refer to...

Страница 3: ...own open without the door for Electric Option details Defogger connector Defogger outlets Outlet 110V Outlet 110V Defogger Switch Blue Light LED Light Switch White Light Electric Shelf 2 7 8 deep for...

Страница 4: ...ee page 6 For Recessed Left or Right side access as determined at the time of order by the door hand For Surface Mount rear access See page 9 NOTE Only remove the Electric Option shelf s front cover t...

Страница 5: ...Circuit Interrupter when used in bathrooms and all other locations required by the National Electric Code NOTES This Electric Option shelf has been factory in stalled Do not alter change or add any wi...

Страница 6: ...cabinet height less 5 8 R O Height RECESSED MOUNTING Rough Opening Note Cabinet installs over nished wall with sheetrock and or tile nishes com pleted 3 4 Flange on all sides of the cabinet will cover...

Страница 7: ...n in stalling this cabinet over the nished surface that includes tile the location of the wire access hole must be repositioned to allow for the thickness of the sheetrock and the tile B Cabinet can b...

Страница 8: ...ly assembled refer to R o formula chart on page 7 to determine the R o required for the unit as assembled Assembling multiple cabinet units 1 Place the units on a 2x4 or 2x6 stud of sufficient horizon...

Страница 9: ...Mounting to wall Refer to pages 3 6 and to Steps 1 5 on page 5 for detailed diagrams Open front panel in Electric Option shelf using the Allen wrench supplied Do not lose the Allen screws provided Ti...

Страница 10: ...iagram EL1 for the access points 110v outlets LED Light Heated Door Defogger switch blue Integral LED Light Switch white 6 White Opal Acrylic shelf is packed separately and must be placed in position...

Страница 11: ...essed Mirrored Cabinets 1 Attach the side mirror kit brackets thru the pre punched holes in your cabinet 2 Try to use the rst row of holes from the top and bottom of your cabinet Using the eight 10 32...

Страница 12: ...t Series 4 Glass Shelves 16 Shelf Clips For cleaning the mirror we recommend using ammonia free sprayway brand glass cleaner which is available at a variety of retail outlets www spraywayinc com conte...

Страница 13: ...ove the door from the carton Hold the door in the upright po sition snap open the factory installed hinges Place the hinge onto the factory installed mount ing plate in the cabinet Toe rst and snap in...

Страница 14: ...Hole Plugs 40 433 00 40 433 00 Cabinet Connectors 4 Cabinet 2 426 00 4 426 00 Cabinet Connectors 6 Cabinet 2 429 00 4 429 00 Cabinet Connector Mounting Screws 8 18 855 10 32 x 1 2 8 18 855 10 32 x 1...

Страница 15: ...4 Model GC 2436 4 Model GC 2430 6 Model GC 2436 6 Qty Part Number Qty Cabinet 4 Cabinet Electric Option 1 GC2430 4 Cab E R or L 1 GC2436 4 Cab E R or L Cabinet 6 Cabinet Electric Option 1 GC2430 6 Ca...

Страница 16: ...and soft closing cushions have a separate lifetime warranty from Blum Inc This warranty is against defects in materials and workmanship as long as the original consumer owns the product This is a warr...

Отзывы: