background image

C

. Install the cabinet with four (4) #10  x 1 1/2” wood screws (supplied).

Use the pre-punched holes above and below the hinge plates (as
shown). do not overtighten. Cover screws with four screw caps (part
#434).

electrician should
make the wire con-
nections and replace the electric option shelf’s front cover with the
three Allen screws provided. Make sure 

not to crimp or pinch the switch

wires and other electrical connections

(Refer to steps 1-5 on pages 5

for detailed diagrams). 

TAKe CARe NoT To sCRATCH THe INsIde WAll oF THe 
CABINeT WITH THe edGes oF THe sHelF CoVeR.

do NoT AlTeR ANY WIRING WITH THe eleCTRIC oPTIoN UNIT
oTHeR THAN MAKING THe INITIAl CoNNeCTIoN.

7

Installing a Recessed & Semi-Recessed 
Mirrored Cabinet Electric Option

A.

determine the rough opening for the cabinet. Refer to “R.o.” formula

chart and diagrams on page 6. opening must be plumb and level. 

In-

stall Electric Option rough wiring with at least 20” excess wire to
enable pull through from either the left of right wire access plastic
bushing installed in the cabinets

. This unit requires a Class A 120V

AC 20 Amp GFCI circuit
breaker (Ground Fault Circuit
Interrupter) required by the
National electric Code. All
electric work must be pro-
vided by a licensed electri-
cian.

SPECIAL NOTE: When in-
stalling this cabinet over
the finished surface that
includes tile, the location
of the wire access hole
must be repositioned to
allow for the thickness of
the sheetrock and the tile.

B.

Cabinet can be hinged on left or right. YoU MUsT oRdeR A leFT

oR RIGHT HANded dooR AT THe TIMe oF oRdeR FoR All MIR-
RoRed CABINeT eleCTRIC oPTIoN UNITs. 
For multiple cabinet units determine the hinge location for each unit
before they are joined together and mark the top of each unit.

Remove the front panel of the electric option shelf using the Allen
wrench supplied. (do NoT lose THe AlleN sCReWs PRoVIded.)

(Refer to steps 1-2 on page 5 for detailed diagrams)

. Pull wire through

access. Insert cabinet in R.o. and center. Cabinet flange covers any
gaps in the R.o. around the cabinet and should overlap the finished
surfaces--sheetrock and/or tile.

C

2x4

Framing

Shown

PLUMB 

LEVEL

1

/

2

 dia.

Wire

Access

Hole 

11 

5

/

8

” 

 

 

 

 

 

 

11 

5

/

8

” 

A

B

Hinge Plate shown for right hinged door.

White Opal

Acrylic Shelf

LED Light

Plastic Bushing -- 

Wire push-through

(Side Access Shown)

Holds wire secure without

clamps.

(Rear Access Bushing-used

in surface mounted cabinets)

THE 1 1/2” ACCESS HOLE MUST BE ALIGNED EXACTLY WITH-
THE PLASTIC BUSHING TO PREVENT CRIMPING.
FOR EXACT DRILL LOCATIONS FOR THE ELECTRIC ACCESS
HOLE SEE DIAGRAMS ON PAGE 6

Rough wire for 
this unit should 
extend 20” from 
either the left or
right wire access 
on the side of the
cabinet to make 
the connections
within the 
Electric Shelf.

Содержание GC1630

Страница 1: ...tric wiring must be by a licensed electrician Recessed or wall mounted installations to be performed by a professional installer See pages 7 through 10 of this manual This unit s electrical connection...

Страница 2: ...r 14 15 Warranty 16 Unpack all parts carefully and protect Glass and Mirror parts during installation Carefully review all parts and read the installation instruction before you start Please refer to...

Страница 3: ...own open without the door for Electric Option details Defogger connector Defogger outlets Outlet 110V Outlet 110V Defogger Switch Blue Light LED Light Switch White Light Electric Shelf 2 7 8 deep for...

Страница 4: ...ee page 6 For Recessed Left or Right side access as determined at the time of order by the door hand For Surface Mount rear access See page 9 NOTE Only remove the Electric Option shelf s front cover t...

Страница 5: ...Circuit Interrupter when used in bathrooms and all other locations required by the National Electric Code NOTES This Electric Option shelf has been factory in stalled Do not alter change or add any wi...

Страница 6: ...cabinet height less 5 8 R O Height RECESSED MOUNTING Rough Opening Note Cabinet installs over nished wall with sheetrock and or tile nishes com pleted 3 4 Flange on all sides of the cabinet will cover...

Страница 7: ...n in stalling this cabinet over the nished surface that includes tile the location of the wire access hole must be repositioned to allow for the thickness of the sheetrock and the tile B Cabinet can b...

Страница 8: ...ly assembled refer to R o formula chart on page 7 to determine the R o required for the unit as assembled Assembling multiple cabinet units 1 Place the units on a 2x4 or 2x6 stud of sufficient horizon...

Страница 9: ...Mounting to wall Refer to pages 3 6 and to Steps 1 5 on page 5 for detailed diagrams Open front panel in Electric Option shelf using the Allen wrench supplied Do not lose the Allen screws provided Ti...

Страница 10: ...iagram EL1 for the access points 110v outlets LED Light Heated Door Defogger switch blue Integral LED Light Switch white 6 White Opal Acrylic shelf is packed separately and must be placed in position...

Страница 11: ...essed Mirrored Cabinets 1 Attach the side mirror kit brackets thru the pre punched holes in your cabinet 2 Try to use the rst row of holes from the top and bottom of your cabinet Using the eight 10 32...

Страница 12: ...t Series 4 Glass Shelves 16 Shelf Clips For cleaning the mirror we recommend using ammonia free sprayway brand glass cleaner which is available at a variety of retail outlets www spraywayinc com conte...

Страница 13: ...ove the door from the carton Hold the door in the upright po sition snap open the factory installed hinges Place the hinge onto the factory installed mount ing plate in the cabinet Toe rst and snap in...

Страница 14: ...Hole Plugs 40 433 00 40 433 00 Cabinet Connectors 4 Cabinet 2 426 00 4 426 00 Cabinet Connectors 6 Cabinet 2 429 00 4 429 00 Cabinet Connector Mounting Screws 8 18 855 10 32 x 1 2 8 18 855 10 32 x 1...

Страница 15: ...4 Model GC 2436 4 Model GC 2430 6 Model GC 2436 6 Qty Part Number Qty Cabinet 4 Cabinet Electric Option 1 GC2430 4 Cab E R or L 1 GC2436 4 Cab E R or L Cabinet 6 Cabinet Electric Option 1 GC2430 6 Ca...

Страница 16: ...and soft closing cushions have a separate lifetime warranty from Blum Inc This warranty is against defects in materials and workmanship as long as the original consumer owns the product This is a warr...