INFORMATION
DISPLAYED
CAUSE
PROCEDURE
Error Sens Maximum
Short circuit of the low level
probe.
Ensure that the probe is against
the combustion fire line.
Please always contact a qualified
technician.
Err Sens Leakage
Short circuit of the leakage probe. Ensure that the probe is against
the combustion fire line.
Please always contact a qualified
technician.
Overload
Excessive power consumption.
Ensure that the ignition probe is
against the combustion fire line.
Please always contact a qualified
technician.
Doorlock
Error
The tank door was opened im-
properly - damaged.
The tank door was damaged.
Do not turn on the Crea7ionEVO
PLUS.
Please always contact a qualified
Ignition
When the resistance is incandes-
cent, the system is igniting bio-
ethanol.
Let the Crea7ionEVO PLUS work
normally.
Error Incl/Vib
The Crea7ionEVO PLUS is not lev-
elled.
Level the Crea7ionEVO PLUS
Click on OFF button (“O”) on the
display.
Et
The Crea7ionEVO PLUS is in
standby mode and indicates fuel
level.
In order to save energy, shutdown
the system in the ON/OFF/ON
button if you are not considering
using the burner.
GlammFire.
PAG./46