5.5—Levelling of combustion fire line
If after having the burner working for more than 20 minutes in order to stabilize the flame, it still does not fill the
combustion line as a whole, it must be leveled.
When installing the Crea7ionEVO PLUS, level the combustion fire line, using the supplied Hex Key Nº4
(G)
and the
screws
(H)
. See
Figure 3
. (In case the burner is between model 1200 and 2400, two screws are required
Figure 3
.)
If the flame does not occupy the entire opening will be necessary to level the combustion fire line.
- Lack of flame on the left: Turn the screw clockwise to clockwise. Parallel turn the screw counter clockwise.
- Lack of flame on the right side: Turn the screw clockwise to clockwise. Parallel turn the right screw counter
clockwise.
- Repeat the procedure described till to get a uniform flame.
G
H
H
H
H
Figure 3
—Screws for levelling the combustion fire line.