gk-medizinmechanik GK Magic 1000 Скачать руководство пользователя страница 18

17 

The bathing cycle / Care & Cleaning 

 

 

To finish, turn the chromed overflow knob in counter clockwise 
direction,  in  order  to  open  the  drain.  Lower  the  bathtub  and 
help  the  patient  out  of  the  water  or  remove  the  bathing  lift 
from the tub. 

 

Before  you  start  a  new  bathing  cycle  you  should  thoroughly 
clean the bathtub. 

 

■ Care & Cleaning 

 

Always clean the plastic parts wet or damp but never dry. 
 

Any  product  used  to  clean  or  disinfect  your  GK  bath  must  be  free 
from any abrasive, alcohol & corrosive ingredients. Never use any 
kind  of  customary  glass  cleansers,  solvents  (e.g.  acetone)  or 
similar detergents or dilutions. Never use harsh or pointed uten-
sils, e.g. rough clothes, scrubbing sponges, scouring pads or any 
tools. If you are in any doubt about your usual cleaning products 
please contact your GK representative before use. 

 

Caution: 

Any  damage  caused  by  unapproved  /  unsuitable  products 
will not be covered by the manufacturer’s warranty. 

 

 

Dark grey and transparent plastic parts: 

 
The dark grey and transparent plastic parts may only be cleaned 
with a maximum of lukewarm water and, if needed, a mild dishwash-
ing soap. We especially recommend our special plastics intensive 
cleanser (details on request). For these parts of the tub 

only use 

very fine textured chamois leather or a microfiber cloth.

 

 
For  the  best  care  for  these  parts  we  recommend  our  special  anti-
static plastics care product (details on request). 
 
 

Remaining tub body parts: 

 
For the other mostly white parts, after use always rinse the bath 
tub thoroughly with the shower hose. Any dirt which adheres to the 
bathtub surfaces must be removed with a soft sponge or cloth and, 
if  necessary,  customary  detergents  (besides  the  above  mentioned 
restrictions).  
 

We recommend using our approved shampoo and bath additive products 
with  your  GK  bath

Other  products  may  cause  more  persistent  dirt 

being harder to clean. 

Содержание GK Magic 1000

Страница 1: ......

Страница 2: ...and translation of both the whole document as well as of any parts thereof Congratulations on your decision to purchase a GK Bathtub You have acquired an Austrian quality prod uct which will considera...

Страница 3: ...er 8 Setting the temperature 9 Temperature display tub fill shower 9 Underwater light 9 Sound Vision 10 Ultrasound 11 Ultrasound cleaning FAQ 11 13 Hydromassage 14 Shampoo Bath additive 14 Disinfectio...

Страница 4: ...ce etc Never leave the patient unattended inside the bathtub Ensure that the equipment is thoroughly cleaned after every use When using disinfection protect your skin and eyes Heed all instructions on...

Страница 5: ...4 3 2 1 8 11 10 5 6 7 Components Components 1 Disinfection 2 Lid 3 Shower 4 Control panel 5 Mixer 6 Shampoo Bath additive dispenser 7 Fill in spout 8 Overflow 9 Hydromassage jets 10 Drain 11 Grab han...

Страница 6: ...5 Components Hydromassage jet Box for care and disinfection liquids USB port Flowmeter with con centration table...

Страница 7: ...Sensor Activation card 6 Button Down 7 Button Up 8 Button Tub fill 9 Button Shower 10 Button Bath additive 11 Button Disinfection 12 Button Shampoo 13 Button Hydromassage Ultrasound 14 Button Underwa...

Страница 8: ...oment and locked Only the sensor ACTIVATION CARD is illuminated with a green backlight The standby mode a prevents unauthorized use of the bathtub and b helps to save energy since due to the deactivat...

Страница 9: ...n TUB FILL the tub starts filling The button starts flashing and the symbol TUB FILL TEMPERATURE lights up The water now flows into the bathtub until the maximum filling level has been reached or the...

Страница 10: ...MPERATURE is illuminated additionally to the flashing button TUB FILL If the shower is active the symbol SHOWER TEMPERATURE is illuminated additionally to the flash ing button SHOWER If tub fill and t...

Страница 11: ...on PLAY PAUSE during playback it is paused and the button starts to shine continu ously When pressing it again the playback contin ues In case the pause exceeds 30 seconds the player resets itself to...

Страница 12: ...ination of the button stops and it can not be used until the next bathing cycle Note The ultrasound transducer is audible The closer any body parts are to the transducer plate the louder the side nois...

Страница 13: ...and spread out through the bathing water What effect does ultrasound have regarding body cleaning Because of the ultrasound millions of tiny gas bubbles are created in the water which collapse again v...

Страница 14: ...take unnecessary risks regarding the life of others May the ultrasound cleaning function be applied to people with pacemakers We have no information about any disruption of a pace maker s functionalit...

Страница 15: ...massage hose coupling is installed then also the jet containing the coupling will be activated immediately without delay upon activation of the whole function Shampoo Bath additive Both of these prod...

Страница 16: ...s infection button is flashing fast 4x sec To start the disinfection procedure take the red hand shower from its holder and press the disinfection but ton The button is flashing now Spray all internal...

Страница 17: ...Always check the water temperature with your bare hand also when using the shower before bringing the water in contact with the patient To add bath additive to the water if installed available press t...

Страница 18: ...y damage caused by unapproved unsuitable products will not be covered by the manufacturer s warranty Dark grey and transparent plastic parts The dark grey and transparent plastic parts may only be cle...

Страница 19: ...h From time to time the hydromassage jet covers should be removed and be cleaned together with the inlet and outlet aper tures separately To do so unscrew the jet covers in counter clockwise direction...

Страница 20: ...infection doesn t work and the button is flashing very fast about 4x sec even though the container is full The disinfection sensor is defective and has to be replaced All the functions are disabled ex...

Страница 21: ...or other dam ages Caution Should you notice any damage to the bathtub either during maintenance or at any other time then the bathtub may not be used any further from that point onward until the damag...

Страница 22: ...0 C Max relative humidity 80 not condensed at 20 C Atmospheric pressure range 500 hPa to 1060 hPa Transport and Storage Ambient temperature range 20 C to 60 C Relative humidity range 80 not condensed...

Страница 23: ...on class I Degree of protection IPX4 Protection type Type B Lifting weight 400 kg Lifting height 400 mm Maximum length 2240 mm Maximum width 930 mm Maximum height 1250 1650 mm Time of guarantee 2 year...

Страница 24: ...ents All product related information is not subject to change for technical production or other reasons Georg Kr mer Ges m b H Co KG A 4061 Pasching Neuhauserweg 14 Tel 43 0 7229 64450 Fax 43 0 7229 7...

Отзывы: