be stopped at any time by pressing the detector’s Programme Button for 4
seconds.
When the D-TectX Signal Strength / Walk Tester receives a signal from the
detector, the R.F. signal strength is displayed on the 4 green LEDs.
For optimum results the D-TectX Signal Strength / Walk Tester should be held
in an upright position.
4 Beeps and 4 green LEDs indicates maximum signal strength.
3 Beeps and 3 green LEDs indicates very good signal strength.
2 Beeps and 2 green LEDs indicates good signal strength.
1 Beep and 1 green LED indicates moderate signal strength.
A weaker R.F. strength is indicated by an increased time between signals
being received.
To preserve battery life on the detector it is recommended to exit the
transmit test mode after testing has been completed.
5. Walk Testing
Ensure the detector is not in transmit test mode.
Set the detector to the required detection range and align the detector head
to cover the required area then replace the detector’s cover.
When the detector has detected movement, the D-TectX Signal Strength /
Walk Tester will beep and the blue DETECTION LED will light. The LED
display will remain lit for 15 seconds, pressing the LEARN button momentarily
will clear the display.
After movement has been detected, no further detection signals will be
transmitted for 8 seconds.
To test any further detectors repeat steps 2 – 5.
After 1 minute of the D-TectX Signal Strength / Walk Tester being turned on
but with no detection or button presses then 3 consecutive beeps and blue
DETECTION LED flashes will be indicated.